3 Technical data and assemblies I nstruction manual SIPLACE SX1/S X2 Edition V2 and V3 3.7 Placement head From software version SC.713.1 Edition 12/2020 132 3.7.5.3 Placement modes for the SIPLACE MultiS tar CPP head The…

100%1 / 366
Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 3 Technical data and assemblies
From software version SC.713.1 Edition 12/2020 3.7 Placement head
131
3.7.5.1 Assembly positions of SIPLACE MultiStar
The SIPLACE MultiStar CPP head can be fitted to the head mount in two different positions:
MultiStar in the top assembly position
In this position, all components can be processed up to a size of 50 mm x 40 mm and a
height of 15.5 mm.
3
MultiStar in the bottom assembly position
In this position, the CPP head places components up to a size of
27 mm x 27 mm and a component height of 6 mm, using the Collect&Place method.
3
Observe the following rules when defining the assembly position:
The head height must be the same for all heads in the same placement area.
Always install the SIPLACE Multistar CPP head in the top assembly position if it is to be com-
bined with the following assemblies:
Stationary component camera
Waffle pack changer (WPC5/WPC6)
–TwinStar
3.7.5.2 Classification of component range to be processed
3
Component
class
Component
size
Assembly
position
*a
of CPP
head
Component
height
Component
camera type
Small compo-
nent
K_BE
03015 -
27 mm x 27 mm
Top Up to 8.5 mm
Head camera,
type 30
Bottom Up to 6.0 mm
Medium sized
component, type
M_BE_1
< 27 x 27 mm
Top
Between 8.5 and
11.5 mm
Stationary compo-
nent camera,
type 33
Bottom Not possible
Medium sized
component, type
M_BE_2
Between
27 mm x 27 mm
and
32 mm x 32 mm
Top 11.5 mm
Bottom Not possible
Large compo-
nent
G_BE
Between
32 mm x 32 mm
and
50 mm x 40 mm
Top Up to 15.5 mm
Stationary compo-
nent camera,
type 33
Bottom Not possible
Tab. 3.7 - 1Classification of component range to be processed
*)a Please observe the rules for assembly position heights in section 3.7.5.1
, page 131.
3 Technical data and assemblies Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
3.7 Placement head From software version SC.713.1 Edition 12/2020
132
3.7.5.3 Placement modes for the SIPLACE MultiStar CPP head
The SIPLACE Multistar CPP head functions with different placement modes, which vary according
to the component class. The setup optimization selects the placement mode with the shortest cy-
cle times. The following table shows the correlation between component class and placement
mode.
Tab. 3.7 - 2 Relations between component class and placement modes
3.7.5.4 Assembly positions of MultiStar in the placement machine
Placement mode Component class
Small component Medium sized
component
Large component
Collect&Place mode Yes No No
Mixed mode Yes Yes No
Advanced
Pick&Place mode
Yes Yes Yes
Placement machine Assembly
position
*a
MultiStar CPP head
Maximum component
height
Vision camera
SIPLACE SX1/SX2 Bottom 6.0 mm Head camera
Top 8.5 mm Head camera
Top only 15.5 mm
Stationary component
camera
Tab. 3.7 - 3Assembly positions of SIPLACE Multistar CPP head in the placement machines
*)a Please observe the rules for assembly position heights in section 3.7.5.1
, page 131.
Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 3 Technical data and assemblies
From software version SC.713.1 Edition 12/2020 3.7 Placement head
133
3.7.5.5 SIPLACE MultiStar CPP in Collect&Place mode
The SIPLACE MultiStar CPP processes small components in this mode.
3
Fig. 3.7 - 8 SIPLACE MultiStar CPP- Collect&Place mode
K_BE Small component (see table 3.7 - 1, page 131)
Type 30 Component camera, type 30
1 ... 12 Order of components taken up
3
Type 30
K_BE