4 Setting up and commissioning Instruction manual SIPLACE SX1/SX 2 Edition V2 and V3 4.2 Infrastructure at the installation location From software ve rsion SC.713.1 Edition 12/2020 194 4.2.3 Main power supply 4 Fig. 4.2 …

Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 4 Setting up and commissioning
From software version SC.713.1 Edition 12/2020 4.2 Infrastructure at the installation location
193
4.2.2.2 Compressed air connection on the placement machine
4
Fig. 4.2 - 2 Compressed air unit on the placement machine
Legend for fig.4.2 - 2
(1) Manometer for supply pressure of gantries 1 and 2
Target pressure: 0.46 ± 0.01 MPa, 4.6 ± 0.1 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(2) Manometer for the machine component supply pressure
Target pressure: 0.5 ± 0.025 MPa, 5 ± 0.25 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(3) Manometer for the bulkcase feeder module supply pressure
Target pressure: 0.25 ± 0.05 MPa, 2.5 ± 0.5 bar (display range: 0 - 0.6 MPa, 0 - 6 bar)
(4) Manometer for inlet pressure
Target pressure: 0.5 - 1.0 MPa, 5 - 10 bar (display range: 0 - 1.0 MPa, 0 - 10 bar)
(5) Compressed air filter
(6) Compressed air connection
(7) Stop valve in the "OPEN" position
(6)
(1)
(2)
(3)
(4)
(5)
(7)

4 Setting up and commissioning Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
4.2 Infrastructure at the installation location From software version SC.713.1 Edition 12/2020
194
4.2.3 Main power supply
4
Fig. 4.2 - 3 Position of power supply in the placement machine
(1) Lock
(2) Main power switch secured to prevent switching on again
(3) Power supply unit behind the cover
4.2.3.1 Danger notes
4
(1)
(2)
(3)
DANGER
Dangerous voltage levels!
The placement machine is supplied with 3 x 380 V~ to 3 x 415 V ± 10 %, 50/60 Hz or op-
tionally with
3 x 200 V~ to 3 x 220 V~ ± 10 %; 50/60 Hz mains voltage. This means that some parts of
the system carry potentially lethal voltages - even when switched off at the main power
switch and with disconnected mains plug.
Incorrect handling of this placement machine can therefore result in death or severe injury
or considerable damage to equipment.
Always follow the applicable accident prevention and DIN regulations (particularly EN
60204, part 1 or IEC 60204, part 1) and the applicable regulations in your own coun-
try.
The covers over the power supply unit may ONLY be opened by appropriately quali-
fied and trained personnel.

Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 4 Setting up and commissioning
From software version SC.713.1 Edition 12/2020 4.2 Infrastructure at the installation location
195
4
4.2.3.2 Checking the main power supply
Check whether the power supply complies with the prescribed machine specifications (see table
in section 3.4
, page 107).
4
DANGER
Lethal voltages under the safety cutoff (CSB) cover!
Under the cover there are components which could still carry lethal voltages for a certain
time, even when the placement machine is switched off and the mains plug has been dis-
connected. After disconnecting the mains plug, wait 5 minutes until the capacitors have
discharged.
Never open the covers.
Only ASM Assembly Systems GmbH&Co.KG service engineers or the machine
owner's service engineers, who have been trained by ASM, may perform work on the
power supply and the safety cutoff (CBS).
PLEASE NOTE
Load peaks in power supply
For technical reasons, load peaks occur in the power supply.
Please contact your power company to clarify the mains impedance, if necessary.