00198661-02_UM_SX12-V3_EN.pdf - 第21页

Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 1 Introduct ion From software version SC.713.1 Edition 12/2020 1.3 Placement mach ine de scription 21 1.3 Placement machine description The SIPLACE SX1 and SX2 pla cem…

100%1 / 366
1 Introduction Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
1.2 Overview From software version SC.713.1 Edition 12/2020
20
1.2.2 SIPLACE SX1/SX2 V2
The SIPLACE SX1/SX2 V2 features a multi-touch monitor with keyboard as a default.
1
Fig. 1.2 - 2 SIPLACE SX1/SX2 V2 placement machine
Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 1 Introduction
From software version SC.713.1 Edition 12/2020 1.3 Placement machine description
21
1.3 Placement machine description
The SIPLACE SX1 and SX2 placement machines demonstrate
High precision,
High configuration flexibility,
Head and gantry modularity
Placement performance up to the high end process range and
A wide ranging component range from 03015 components to a size of
125 mm x 10 mm.
Three placement methods are possible for processing the components:
Collect&Place,
Pick&Place and
A combination of Collect&Place and Pick&Place (mixed mode).
The SIPLACE SX1 placement machine consists of one gantry while the SIPLACE SX2 placement
machine has two gantries. The head and gantry modularity principle developed by SIPLACE al-
lows you to change placement heads and gantries quickly and easily. For an overview of the
placement head configuration, refer to section 1.3.3
from page 25.
These can be quickly and accurately positioned by linear motors, moving independently of one
another in the X and Y directions.
The SX1/SX2 machine supports use of either the SIPLACE single conveyor or the flexible dual
conveyor.
There are two locations available for supplying components. These can be fitted with component
trolleys and configured with up to 60 tracks.
Alternatively, you can also dock a waffle pack changer (WPC5 or WPC6) at each of the two loca-
tions. If a WPC5/WPC6 is set up at one of the locations, a component trolley with 30 tracks must
be configured for the other location.
1 Introduction Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
1.3 Placement machine description From software version SC.713.1 Edition 12/2020
22
1.3.1 Overview of SIPLACE SX placement machines
The SIPLACE SX must be prepared for a gantry upgrade. The SIPLACE SX placement machines
are available in different variants.
1
The head configurations available may be limited, according to the design concerned.
Type Gantries Description
SIPLACE SX +
Without gan-
try
The placement machine is prepared for a gantry up-
grade (SX1), i.e. a trailing cable and two Gantry Control
Units (GCU) are preinstalled for one gantry.
SIPLACE SX +
Prepared
Without gan-
try
The placement machine is prepared for a gantry up-
grade (SX1/2), i.e. two trailing cables and three Gantry
Control Units (GCU) are preinstalled for two gantries.
SIPLACE SX1
unprepared
One gantry The placement machine is not prepared for a gantry
upgrade, i.e. the trailing cable and two Gantry Control
Units (GCU) are preinstalled for one gantry. An upgrade
to SIPLACE SX2 needs to be performed by the SI-
PLACE Service team.
SIPLACE SX1
prepared
One gantry The placement machine is prepared for a gantry up-
grade (SX2) i.e. two trailing cables and three Gantry
Control Units (GCU) are preinstalled for two gantries.
SIPLACE SX2
Two gantries The placement machine can be torn down to give a
SIPLACE SX1 Prepared. The machine is then prepared
for a gantry upgrade to SX2, i.e. two trailing cables and
three Gantry Control Units (GCU) are available.