00198661-02_UM_SX12-V3_EN.pdf - 第315页

Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 6 Station e xtensi ons From software version SC.713.1 Edition 12/2020 6.4 Waffle pack ch anger (WPC5/WPC6) 315 6.4.9 Controls 6 Fig. 6.4 - 4 WPC - controls (1) EMERGEN…

100%1 / 366
6 Station extensions Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
6.4 Waffle pack changer (WPC5/WPC6) From software version SC.713.1 Edition 12/2020
314
6.4.7 Installation notes for WPC5/WPC6
The WPC5/WPC6 can be docked onto the left side (at location 1 or location 2) of the SX placement
machine.
6.4.8 Dimensions with WPC5/WPC6
6
Fig. 6.4 - 3 Dimensions of SX placement machine with WPC5/WPC6
(1) 3000 mm
(2) 700 mm
(3) 445 mm
(4) 769 mm
(5) Location for component trolley with 30 tracks
Instruction manual SIPLACE SX1/SX2 Edition V2 and V3 6 Station extensions
From software version SC.713.1 Edition 12/2020 6.4 Waffle pack changer (WPC5/WPC6)
315
6.4.9 Controls
6
Fig. 6.4 - 4 WPC - controls
(1) EMERGENCY STOP button
(2) Main switch
(3) Crank for raising or lowering the chassis
(4) Safety door
(5) Waffle pack tray storage unit
(6) Non-stop module (WPC6 only)
(3)
(2)
(1)
(4)
(5)
(6)
6 Station extensions Instruction manual SIPLACE SX1/SX2 Edition V2 and V3
6.4 Waffle pack changer (WPC5/WPC6) From software version SC.713.1 Edition 12/2020
316
6.4.9.1 Safety features
EMERGENCY STOP button 6
After pressing the EMERGENCY STOP button, the entire system, with SIPLACE SX and Waffle
Pack Changer, is immediately stopped. After releasing the EMERGENCY STOP button, the entire
system can be restarted again by pressing the start button on the SX placement machine. Place-
ment can then be continued or terminated.
6
Safety door 6
When you open the protective door, the lifting axis and the feed axis of the Waffle Pack Changer
are stopped. When the door is closed again, the Waffle Pack Changer continues its operation.
6
Non-stop module (WPC6 only) 6
Waffle pack trays can be refilled or extracted during operations via the flap in the non-stop module,
without stopping the SIPLACE SX. The operating control indicates whether a waffle pack tray is
in the non-stop module, whether the non-stop module is empty or whether a waffle pack tray is
currently being moved.
6
PLEASE NOTE
Watch out for any incompletely placed PCBs.
CAUTION
Do not open the Waffle Pack Changer protective door while a component is being
picked up by the Waffle Pack Changer.
CAUTION
Triggering the emergency STOP by opening the flap!
If the operating control flashes, the waffle pack tray is being moved inside the non-stop
module and the activity has not yet been completed. Opening the flap triggers the emer-
gency STOP.
To open the flap, wait until the operating control is no longer flashing.