2.3 Error IDs and Remedial Procedures Error ID Item Description 0101000 T able X Origin Zeroing opn. was incompleted, within specified time. (Cause 1) Dirt adheres to the sensor and the optical beam is shielded. (Cause 2…

100%1 / 387
2.2 Error IDs and Controlled Areas
Basic System of Error IDs
An error ID is expressed by 7 digits (decimal number) as follows.

Major Classification of "Operating Axis", "Process Error", and
"Teaching Operation"
Error IDs and Controlled Areas
Table 4B5
Error ID Operating Axis Error ID Process Error
01 Table-X Axis 15 Safety Device
02 Table-Z Axis 16 Self-Diagnostics
03 Placement Z Correction Table
Axis 17 Material Shortage
04 Screen Y Axis 18 P.C.B. Recognition
05 Squeegee Driving Axis 19 Screen Recognition
06 P.E.C. Recognition Camera X Axis 20 Cleaning
07 P.E.C. Recognition Camera Y Axis 21 Operators Error
08 Screen Recognition Camera X Axis 22 Others
09 P.C.B. Backup Axis
10 Table Chute Width
11 Input Conveyor
12 Output Conveyor
13 P.C.B. Transfer
14 Squeegee Head
2.2 Error IDs and Controlled Areas
0009-001 Chapter 2 2 7 AFU01ETRP
2.3 Error IDs and Remedial Procedures
Error ID Item Description
0101000 Table X Origin Zeroing opn. was incompleted, within specified time.
(Cause 1) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2) The sensor is defective.
(Cause 3) The driver is malfunctioning or an error has occurred during communication
with the host CPU.
(Remedy 1) Wipe off dirt on the sensor and zero Table X again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine
again. After that, zero Table X.
If this operation does not reset the machine to its normal condition, the
driver may be defective. Contact our service personnel for details.
0102000 Table X Origin Detect lost pulse error.
(Cause 1) The motor is overloaded and has a loss of synchronism.
(Remedy 1) Check for any obstacle around the table X axis and then perform the
zeroing operation.
If this operation does not reset the machine to its normal condition, con-
tact our service personnel for details.
0103000 Table X Limit (+) Limit error has been detected.
0104000 Table X Limit (-) Limit error has been detected.
(Cause 1) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2) The sensor is defective.
(Cause 3) The driver is malfunctioning or an error has occurred during communication
with the host CPU.
(Remedy 1) Wipe off dirt on the sensor and zero Table X again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine
again. After that, zero Table X.
If this operation does not reset the machine to its normal condition, the
driver may be defective. Contact our service personnel for details.
2.3 Error IDs and Remedial Procedures
0106-002 Chapter 2 2 8 AFU01ETRP
Error ID Item Description
0105000 Table X Limit Driver alarm signal was detected.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If this operation does not reset the machine to its normal condition, con-
tact our service personnel for details.
0108000 Table X Limit Driver Over-Heat
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If this operation does not reset the machine to its normal condition, con-
tact our service personnel for details.
0109000 Table X Limit Operatuon was incompleted, within specified time.
(Cause 1) The driver is malfunctioning or an error has occurred during communication
with the host CPU.
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, perform the zeroing operation.
If this operation does not reset the machine to its normal condition, the
driver may be defective. Contact our service personnel for details.
0110000 Table X Interlock Table-Z Axis is not at safety area.
(Cause 1) The table Z axis interlock sensor (BPH055) is defective.
(Cause 2) The operation timing is shifted from the normal one.
(Remedy 1) Check how the sensor is working in “Device Check” window (submenu).
When the sensor is not working, it is required to replace the sensor with
a new one. Contact our service personnel for details.
(Remedy 2) Shut down the power of the machine once and power up the machine
again. After that, restart the operation.
When the same error still occurs, contact our service personnel for de-
tails.
2.3 Error IDs and Remedial Procedures