2OM-1104-001.pdf - 第214页
Error ID Item Description 1631000 Pattern Program Illegal pattern program Data Error (Cause 1) An illegal value is set in pattern program data. (Remedy 1) Press the [PRGM. CHECK] button in the "ERROR" window an…

Error ID Item Description
1619000 Pattern Program
Data Error
1620000 Pattern Program
Data Error
1621000 Pattern Program
Data Error
1622000 Pattern Program
Data Error
1623000 Pattern Program
Data Error
1624000 Pattern Program
Data Error
1625000 Pattern Program
Data Error
1626000 Pattern Program
Data Error
1627000 Pattern Program
Data Error
1628000 Pattern Program
Data Error
1629000 Pattern Program
Data Error
1630000 Pattern Program
Data Error
(Cause 1) The motor controller node (APMD017) failed in the communication with the
host computer.
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, restart the operation.
When the same error still occurs, contact our service personnel for de-
tails.
2.3 Error IDs and Remedial Procedures
0106-001 Chapter 2 2 58 AFU01ETRP

Error ID Item Description
1631000 Pattern Program Illegal pattern program
Data Error
(Cause 1) An illegal value is set in pattern program data.
(Remedy 1) Press the [PRGM. CHECK] button in the "ERROR" window and check
the contents. After that, set the correct value(s).
1701000 Squeegee Life Front squeegee exceeded life limit.
(Cause 1) The frequency of the front squeegee use has exceeded the limitation.
(Remedy 1) Change the front squeegee and select the "Printed" data field of the re-
placed squeegee in the "Auto Stop Info" tab sheet. After that, press the
[Counter Clear] button.
1702000 Squeegee Life Rear squeegee exceeded life limit.
(Cause 1) The frequency of the rear squeegee use has exceeded the limitation.
(Remedy 1) Change the rear squeegee and select the "Printed" data field of the re-
placed squeegee in the "Auto Stop Info" tab sheet. After that, press the
[Counter Clear] button.
1801000 Fiducial Mark #1
1801001 Fiducial Mark #1 [Camera ID] exceeds the range of setting.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If the machine is not reset to its normal condition, shut down the power of
the machine once and power up the machine again. After that, re-start
the operation.
When the same error still occurs, contact our service personnel for de-
tails.
2.3 Error IDs and Remedial Procedures
0106-001 Chapter 2 2 59 AFU01ETRP

Error ID Item Description
1801003 Fiducial Mark #1 [Camera Gain] exceeds the range of setting.
1801004 Fiducial Mark #1 [Camera Level] exceeds the range of setting.
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
1801011 Fiducial Mark #1 [Mark Size D1] exceeds the range of setting.
1801012 Fiducial Mark #1 [Mark Size D2] exceeds the range of setting.
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
1801014 Fiducial Mark #1 [Mark Judge Level] exceeds the range of setting.
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
2.3 Error IDs and Remedial Procedures
0106-001 Chapter 2 2 60 AFU01ETRP