Error ID Item Description 1305000 P .C.B. T ransfer PCB transfer from inp. conv . was not completed within speci- Overtime fied time. (Cause 1) The conveyor speed is too slow . (Cause 2) The P .C.B. detection sensor (BPH…

100%1 / 387
Error ID Item Description
1213000 Output Conveyor Zeroing Opn. Not Complete
Width Origin
(Cause 1) The motor axis was activated before the zeroing operation was completed.
(Remedy 1) Perform the zeroing operation.
1301000 P.C.B. Supply P.C.B. transfer signal was not off after P.C.B. detect.
1302000 P.C.B. Supply P.C.B. transfer signal is off before P.C.B. detect.
(Cause 1) Communication Error with Input Machine
(Remedy 1) Check the P.C.B. transfer signal from the input machine in the "Org./
Signal Info." tab sheet.
When the problem cannot be solved, contact our service personnel for
details.
1303000 Input Conveyor PCB from inp. machine was not received within specified
Overtime time.
(Cause 1) The set value of the timer is too short.
(Cause 2) The conveyor speed is too slow.
(Cause 3) The P.C.B. detection sensor (BPH041) is not working.
(Remedy 1) Set a larger parameter in the "Output Conveyor" text box of the "Timer
Setting (sec)" group box in the "Transfer Mode Set-up" tab sheet.
(Remedy 2) Turn up the variable resistor of the L conveyor speed control.
(Remedy 3) Check how the sensor is working in "Device Check" window (submenu).
When the sensor is not working, it is required to adjust the sensor posi-
tion or replace the sensor with a new one.
Contact our service personnel for details.
1304000 Output Conveyor PCB was not transferred to outp.conv. within specified time.
Overtime
(Cause 1) The set value of the timer is too short.
(Cause 2) Communication Error with Output Machine
(Remedy 1) Set a larger parameter in the "Output Conveyor" text box of the "Timer
Setting (sec)" group box in the "Transfer Mode Set-up" tab sheet.
(Remedy 2) Contact our service personnel for details.
2.3 Error IDs and Remedial Procedures
0106-001 Chapter 2 2 47 AFU01ETRP
Error ID Item Description
1305000 P.C.B. Transfer PCB transfer from inp. conv. was not completed within speci-
Overtime fied time.
(Cause 1) The conveyor speed is too slow.
(Cause 2) The P.C.B. detection sensor (BPH071) is not working.
(Remedy 1) Turn up the variable resistor of the L conveyor speed control.
(Remedy 2) Check how the sensor is working in "Device Check" window (submenu).
When the sensor is not working, it is required to adjust the sensor posi-
tion or replace the sensor with a new one.
Contact our service personnel for details.
1306000 P.C.B. Transfer PCB transfer to outp.conv. was not completed within speci-
Overtime fied time.
(Cause 1) The P.C.B. arrival check sensor (BPH044) is not working.
(Remedy 1) Check how the sensor is working in "Device Check" window (submenu).
When the sensor is not working, it is required to adjust the sensor posi-
tion or replace the sensor with a new one.
Contact our service personnel for details.
1307000 P.C.B. Transfer PCB was not transferred from outp.conv. within specified
Overtime time.
(Cause 1) The P.C.B. passage check sensor (BPH045) is not set in the E/NR (Light
Emitted and Not Received) or the E/R (Light Emitted and Received) mode.
(Remedy 1) Check how the sensor is working in "Device Check" window (submenu).
When the sensor is not working, it is required to adjust the sensor posi-
tion or replace the sensor with a new one.
Contact our service personnel for details.
2.3 Error IDs and Remedial Procedures
0106-001 Chapter 2 2 48 AFU01ETRP
Error ID Item Description
1308000 P.C.B. Transfer PCB transfer to input conv. was not completed within speci-
Overtime fied time.
(Cause 1) The P.C.B. detection sensor (BPH041) is not set in the E/NR (Light Emitted
and Not Received) or the E/R (Light Emitted and Received) mode.
(Cause 2) The conveyor speed is too slow.
(Remedy 1) Check how the sensor is working in "Device Check" window (submenu).
When the sensor is not working, it is required to adjust the sensor posi-
tion or replace the sensor with a new one.
Contact our service personnel for details.
(Remedy 2) Turn up the variable resistor of the L conveyor speed control.
1309000 Input Conveyor A P.C.B. was transferred by the conveyor while the P.C.B.
Interlock backup axis was moving up.
1310000 Output Conveyor A P.C.B. was transferred by the conveyor while the P.C.B.
Interlock backup axis was moving up.
(Cause 1) Dirt adheres to the backup axis near origin sensor and the optical beam is
shielded.
(Cause 2) The backup axis near origin sensor is defective.
(Cause 3) The backup axis driver is malfunctioning or an error has occurred during
communication with the host CPU.
(Remedy 1) Wipe off the dirt on the sensor and zero the P.C.B. backup axis again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine
again. After that, perform the zeroing operation.
If this operation does not reset the machine to its normal condition, the
driver may be defective. Contact our service personnel for details.
1312000 P.C.B. Transfer Input Conveyor motor was running.
Interlock
1313000 P.C.B. Transfer Output conveyor motor was running.
Interlock
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, restart the operation.
When the same error still occurs, contact our service personnel for de-
tails.
2.3 Error IDs and Remedial Procedures
0106-001 Chapter 2 2 49 AFU01ETRP