Error ID Item Description 1901024 Screen Fiducial [Recog.Area Y] exceeds the range of setting. Mark #1 1901025 Screen Fiducial [Color] exceeds the range of setting. Mark #1 1901026 Screen Fiducial Could not get Screen im…

100%1 / 387
Error ID Item Description
1901005 Screen Fiducial [Camera Mag. X] exceeds the range of setting.
Mark #1
1901006 Screen Fiducial [Camera Mag. Y] exceeds the range of setting.
Mark #1
1901007 Screen Fiducial [Gain, Level] exceeds the range of setting.
Mark #1
1901008 Screen Fiducial [Mark] exceeds the range of setting.
Mark #1
1901009 Screen Fiducial [Mark Code] exceeds the range of setting.
Mark #1
1901010 Screen Fiducial [Mark Code] exceeds the range of setting.
Mark #1
1901011 Screen Fiducial [Mark Size D1] exceeds the range of setting.
Mark #1
1901012 Screen Fiducial [Mark Size D2] exceeds the range of setting.
Mark #1
1901013 Screen Fiducial [Mark Pol.] exceeds the range of setting.
Mark #1
1901014 Screen Fiducial [Mark Judge Level] exceeds the range of setting.
Mark #1
1901015 Screen Fiducial [PCB Pattern ID] exceeds the range of setting.
Mark #1
1901016 Screen Fiducial [P.E.C Recog. Offset] exceeds the range of setting.
Mark #1
1901017 Screen Fiducial [P.E.C Recog. Gain] exceeds the range of setting.
Mark #1
1901018 Screen Fiducial [Jig Size X] exceeds the range of setting.
Mark #1
1901019 Screen Fiducial [Jig Size Y] exceeds the range of setting.
Mark #1
1901020 Screen Fiducial [Jig Figure] exceeds the range of setting.
Mark #1
1901021 Screen Fiducial [Jig Line Width] exceeds the range of setting.
Mark #1
1901022 Screen Fiducial [Algorism] exceeds the range of setting.
Mark #1
1901023 Screen Fiducial [Recog.Area X] exceeds the range of setting.
Mark #1
(Cause 1) Same as "Fiducial Mark #1"
(Remedy 1) Same as "Fiducial Mark #1"
2.3 Error IDs and Remedial Procedures
0106-001 Chapter 2 2 64 AFU01ETRP
Error ID Item Description
1901024 Screen Fiducial [Recog.Area Y] exceeds the range of setting.
Mark #1
1901025 Screen Fiducial [Color] exceeds the range of setting.
Mark #1
1901026 Screen Fiducial Could not get Screen image.
Mark #1
1901027 Screen Fiducial X-cordinate error of measuring point was extensive.
Mark #1
1901028 Screen Fiducial Y-cordinate error of measuring point was extensive.
Mark #1
1901029 Screen Fiducial Image around fiducial mark was unstable.
Mark #1
1901030 Screen Fiducial Error of mark figure similitude was extensive.
Mark #1
1901031 Screen Fiducial Error of mark similitude or mark size was extensive.
Mark #1
1901032 Screen Fiducial Specified mark was not found in window of recog.monitor.
Mark #1
1901033 Screen Fiducial Unavailable camera magnification was set.
Mark #1
1901034 Screen Fiducial Abnormal data was transferred to recog.unit.
Mark #1
1901035 Screen Fiducial Unavailable fiducial mark code was set.
Mark #1
1901036 Screen Fiducial Unavailable fiducial mark size D1 was set.
Mark #1
1901037 Screen Fiducial Unavailable fiducial mark size D2 was set.
Mark #1
1901038 Screen Fiducial Unavailable fiducial mark polality was set.
Mark #1
1901039 Screen Fiducial Unavailable fiducial mark angle was set.
Mark #1
1901040 Screen Fiducial Unavailable fiducial mark area was set.
Mark #1
1901041 Screen Fiducial JIG not found
Mark #1
(Cause 1) Same as "Fiducial Mark #1"
(Remedy 1) Same as "Fiducial Mark #1"
2.3 Error IDs and Remedial Procedures
0106-001 Chapter 2 2 65 AFU01ETRP
Error ID Item Description
1901042 Screen Fiducial Recognition system error.
Mark #1
1901043 Screen Fiducial Recognition system error.
Mark #1
1901044 Screen Fiducial Could not get image at normal light.
Mark #1
1901045 Screen Fiducial Could not get image at ring light.
Mark #1
1901046 Screen Fiducial Field no. was out of range.
Mark #1
1901047 Screen Fiducial Pinting test failed.
Mark #1
1901048 Screen Fiducial Could not get screen image
Mark #1
1901049 Screen Fiducial Could not move indpection window.
Mark #1
1901050 Screen Fiducial Could not cut indpection window.
Mark #1
1901051 Screen Fiducial Could not soecified opening area size.
Mark #1
1901052 Screen Fiducial Could not send inspection window data.
Mark #1
1901053 Screen Fiducial Could not reimage bridge insoection window.
Mark #1
1901054 Screen Fiducial Could not reimage bridge insoection window(rotation).
Mark #1
1901055 Screen Fiducial PAD area soze exceeds the max eange(6.5mm
2
).
Mark #1
1901056 Screen Fiducial Recog. transaction time over.
Mark #1
(Cause 1) Same as "Fiducial Mark #1"
(Remedy 1) Same as "Fiducial Mark #1"
1902000 Screen Fiducial (Same as "Fiducial Mark #1")
Mark #2
(Cause 1) Same as "Fiducial Mark #1"
(Remedy 1) Same as "Fiducial Mark #1"
2.3 Error IDs and Remedial Procedures