Error ID Item Description 1 1 12000 Input Conveyor The data was detected outside of the possible range. Width Data (Cause 1) Self-Diagnostics Error Message (Remedy 1) Zero all axes and re-start the operation. If the mach…

Error ID Item Description
1109000 Input Conveyor Operation was incompleted, within specified time.
Width Driver
(Cause 1) The driver is malfunctioning or an error has occurred during communication
with the host CPU.
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, perform the zeroing operation.
If this operation does not reset the machine to its normal condition, the
driver may be defective. Contact our service personnel for details.
1110000 lnput Conveyor The table X axis has approached too close to the input con-
Width Interlock veyor.
(Cause 1) The table X-axis interlock sensors (BPH056 and BPH057) are defective.
(Cause 2) The operation timing is shifted from the normal one.
(Cause 3) The conveyor width was adjusted when the table X axis was brought close
to the right or the left. (during the manual operation)
(Remedy 1) Check how the sensors are working in "Device Check" window (submenu).
When the sensors are not working, it is required to replace the sensors
with new ones. Contact our service personnel for details.
(Remedy 2) Shut down the power of the machine once and power up the machine
again. After that, restart the operation.
When the same error still occurs, contact our service personnel for de-
tails.
(Remedy 3) Perform the zeroing operation and re-start the operation.
1111000 Input Conveyor PCB was exist on conveyor.
Width Interlock
(Cause 1) No operation is possible because a P.C.B. still exists on the conveyor.
(Cause 2) The P.C.B. detection sensors (BPH040 and BPH041) are defective.
(Remedy 1) Remove the P.C.B. and re-start the operation.
(Remedy 2) Check how the sensors are working in "Device Check" window (submenu).
When the sensors are not working, it is required to replace the sensors
with new ones.
Contact our service personnel for details.
2.3 Error IDs and Remedial Procedures
0106-001 Chapter 2 2 43 AFU01ETRP

Error ID Item Description
1112000 Input Conveyor The data was detected outside of the possible range.
Width Data
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If the machine is not reset to its normal condition, shut down the power of
the machine once and power up the machine again. After that, re-start
the operation. When the same error still occurs, contact our service per-
sonnel for details.
1113000 Input Conveyor Zeroing Opn. Not Complete
Width Origin
(Cause 1) The motor axis was activated before the zeroing operation was completed.
(Remedy 1) Perform the zeroing operation.
1201000 Output Conveyor Zeroing opn. was incompleted, within specified time.
Width Origin
(Cause 1) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2) The sensor is defective.
(Cause 3) The driver is malfunctioning or an error has occurred during communication
with the host CPU
(Remedy 1) Wipe off the dirt on the sensor and zero the output conveyor width axis
again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine
again. After that, perform the zeroing operation.
If this operation does not reset the machine to its normal condition, the
driver may be defective. Contact our service personnel for details.
1202000 Output Conveyor Detect lost pulse error.
Width Origin
(Cause 1) The motor is overloaded and has a loss of synchronism.
(Remedy 1) Check for any obstacle around the output conveyor width axis and per-
form the zeroing operation.
If this operation does not reset the machine to its normal condition, con-
tact our service personnel for details.
2.3 Error IDs and Remedial Procedures
0106-001 Chapter 2 2 44 AFU01ETRP

Error ID Item Description
1205000 Output Conveyor Driver alarm signal was detected.
Width Driver
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If this operation does not reset the machine to its normal condition, con-
tact our service personnel for details.
1208000 Output Conveyor Driver Over-Heat
Width Driver
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If this operation does not reset the machine to its normal condition, con-
tact our service personnel for details.
1209000 Output Conveyor Operation was incompleted, within specified time.
Width Driver
(Cause 1) The driver is malfunctioning or an error has occurred during communication
with the host CPU.
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, perform the zeroing operation.
If this operation does not reset the machine to its normal condition, the
driver may be defective. Contact our service personnel for details.
2.3 Error IDs and Remedial Procedures
0106-001 Chapter 2 2 45 AFU01ETRP