CACCIA Manual 1 Caccia Student Guide Issue 04/2007 EN 13 → A "comparison file " will be generated. Note We recomm end that you include the Caccia version numb er in the file names, for subsequen t ref- erence (…

100%1 / 298
1 Caccia Student Guide CACCIA Manual
Issue 04/2007 EN
12
Use extended CAN IDs
This option has been introduced due to an address extension. 1
Enable this option if you have installed one of the following CAN cards: 1
CANAS
CANBLUE
–CANDY
The drivers for these CAN cards need to be informed that they are to operate in extended CAN
mode. This information is required at program start. 1
Check presence of transceiver
If this option is disabled, Caccia can be used "offline" for training purposes. 1
Note
This option only works with KVASER and CANcardXL cards 1
Assignment: CAN Card - Net
Recommended setting: Use default configuration from the machine configuration.
Specify baudrate selection
Recommended setting: Use default configuration from the machine configuration.
Specify the download security
Recommended setting: Allow suitable download file only.
1
Embedded Software Check (eSW) Check DataBase
The eSW Check compares the SW versions of the individual CAN subsystems with the latest SW
version. This functions allows you to detect differences in the software versions used by the CAN
subsystems. 1
Before you can use the eSW Check Database option, the following preparations need to be per-
formed: 1
Copy the firmware files (FW files) from the C:\SRProgramme\CANFw folder of the current sta-
tion software release. Specify a suitable folder on the service laptop as the target for these files
(e.g. C:\FW_Vergleich).
Click on the Create File from Path button. A dialog box for searching a folder will open. Select
the folder chosen on the service laptop as the target for the FW files (e.g. C:\FW_Vergleich)
and click on OK.
CACCIA Manual 1 Caccia Student Guide
Issue 04/2007 EN
13
A "comparison file" will be generated.
Note
We recommend that you include the Caccia version number in the file names, for subsequent ref-
erence (e.g. C:\FW_14_0_88_Vergleich). 1
When the firmware check is performed (eSW) for the CAN subsystems, all versions will be com-
pared to the contents of this reference file, (Siehe “Opening the Subsystem Control Center with
(eSW) Firmware Check” auf Seite 17). 1
1 Caccia Student Guide CACCIA Manual
Issue 04/2007 EN
14
1.2 Basic Functions
1.2.1 Opening the Subsystem Control Center
Click on the button to open the Subsystem Control Center dialog box:
1
Fig. 1 - 7 Subsystem Control Center dialog box
1
1
Button Description / Action
Collapse All Closes the open tree structure completely.
Clear All Disables the subsystems currently active.
Log to File
Saves the structure of the configured machine, including
all subsystems, as a text file.