CAN Bus Workshop_Version 03__06-2008_EN.pdf - 第164页
1 Caccia Student Guide CACCIA Manual Issue 04/2007 EN 72 1.1 1 One Wire Bus The introduction of the messag e loop in software ver sion 505 (601) made it necessa ry to either reduce the number of inputs/ou tputs or to ins…

CACCIA Manual 1 Caccia Student Guide
Issue 04/2007 EN
71
Affected Range 1
This is where you can define the address range for which a trace is to be recorded: 1
1
1
Decode 1
Set a tick at Decode if you want to display the figures in the right column of the recording field in
short clear text passages. 1
Note
This option is not suitable for remote diagnosis by R&D. 1
→ Complete the recording by selecting Trace - Stop Trace from the menu. The recording field
will return to beige.
→ When you leave the CanScope dialog box, the file last chosen will remain as the prompt value
for the next time.
1
Example:
Contents of file: CAN control window Net 1 @11_03_2005_16_56_08.txt
(This file name is assigned automatically.) 1
T: 257122.779.20 CanId: 07d0 L: 6 Data: 6e 11 01 04 28 10
T: 257122.779.60 CanId: 07d1 L: 4 Data: 6e 00 1d 32
T: 257123.725.50 CanId: 07d0 L: 6 Data: 6e 11 01 04 28 11
T: 257123.725.80 CanId: 07d1 L: 4 Data: 6e 00 1e 4b
T: 257124.671.40 CanId: 07d0 L: 6 Data: 6e 11 01 01 28 10
1
Add All
Records the communication protocols for all CAN telegrams.
Note The evaluation may be extensive if this option is chosen.

1 Caccia Student Guide CACCIA Manual
Issue 04/2007 EN
72
1.11 One Wire Bus
The introduction of the message loop in software version 505 (601) made it necessary to either
reduce the number of inputs/outputs or to install an additional I/O module. In order to save space
and minimize costs, we decided to introduce the "one wire bus system".
The one wire bus controls the nozzle changer in all 4 sectors, transmits the temperature values
from the sensors at the head boards and reads out the gantry data.
Tasks:
(1) Control the Nozzle changer 6/12 C&P heads (1st and 2nd row).
2. Control the Nozzle changer 20 C&P heads (1st and 2nd row), with magazine monitoring
(3) 2 Temperature sensors per gantry, fixed to the head plate.
(4) Storage of gantry identification on an EEPROM.
(A differentiation is made between Plate gantry CFK-02, D
esign To Cost (DTC) gantry CFK-04
and CFK 06 gantry. This means that the machine database loaded for the dynamic parameters
of the main axis differs according to the gantry type concerned).
5. Option: Monitoring of the reject box
1.11.1 One Wire Bus - Structure
As the name indicates, the data are transferred (serial transfer) via a single wire, to the relevant
subsystem.
The one wire bus system is used for processes where time is not a critical factor and can be real-
ized as a single master bus with „any number“ of slaves (stations).

CACCIA Manual 1 Caccia Student Guide
Issue 04/2007 EN
73
1.11.1.1 Basic Structure
The one wire bus system consists in principle of a master with EEPROM (control unit), which con-
trols the various submodules such as A/D converters, EEPROM, temperature and I/O modules.
Each communication branch is equipped with an upstream coupler, which opens the branch for
data transfer.
Fig. 1 - 47 One wire bus principle
Slave
Master
Coupler
E²
A/D A/DA/D I/O
Coupler
E²
°C I/O°C
E²
Slave