00191413-01.pdf - 第29页
User Manual Line Computer UNIX 1 Hardware / Software Install ation Software Version 501.xx 01/99 Issue 1.2 Software Install ation 1 - 11 After co nvertin g the G F-Bibli othek (p ackag e form li brary) , the sel ectio n …

1 Hardware / Software Installation User Manual Line Computer UNIX
1.2 Software Installation Software Version 501.xx 01/99 Issue
1 - 10
● Remove Installation Diskette and insert the CD-ROM.
● Press any key on the keyboard.
The system is rebooted. When the booting procedure has been completed, the following lines
are displayed:
login:
● Enter
plr
after "login:" and press RETURN.
Password:
● Enter
plr
after "Password" and press RETURN.
The CD-ROM is now read in. This takes approx. 10 minutes.
While the data are being read in, information about the ongoing activities is displayed.
If no data are available in the line computer, the following query appears:
There is no user data (SDH) on the line computer.
Do you want to install default libraries (GF-/BE-/RI-Bibliothek..) [y/n]
● Enter
y
and confirm your entry by pressing RETURN. The default libraries are now installed.
NOTE
If
n
was entered, only the ST-library is installed.
The following query appears:
Converting GF-Bibliothek (7xx/8xx-nozzle)
You can update the GF-Bibliothek later too.
Do you want to update 7xx/8xx-nozzles
and sensor specific information (10/12/13/14/17.SST) now [y/n]
● Enter
y
and confirm your entry by pressing RETURN.
The 7xx/8xx type nozzles and the sensor types 10, 12, 13, 14, 17 are being entered in the GF-
files. Previously entered 7xx-nozzles are retained.
In the standard range (GF-nos. 1 through 1499) the allocation of the nozzles is carried out via a Table.
The allocations of customer-specific package forms are calculated.
In the Import/Expor directory a "GFupgrade403.log" file is created containing a list of all alloca-
tions. The content of the file can be displayed and printed out by means of the file display option
(see chapt. 4, section 4.5).
Any incorrectly assigned nozzles can be changed subsequently by means of the Package Form
Editor.
User Manual Line Computer UNIX 1 Hardware / Software Installation
Software Version 501.xx 01/99 Issue 1.2 Software Installation
1 - 11
After converting the GF-Bibliothek (package form library), the selection possibilities for the configuration
of the desktop ("Desk-Configuration") are displayed on the screen.
1) Programming
2) Controlling
Enter a value in between [1-2]:
Enter
1
if the desktop (see chapt. 3) is to be set up as a programming station, or enter
2
if the desktop
is to be set up as a control station, and confirm your entry by pressing RETURN.
A menu for the selection of a production line (example) is displayed only if line configurations exist (see
chapt. 12, section 12.2.1):
1) SMT
2) ERP_L2
Please select a line [1-2]:
● Enter number of line (e.g.
1
for SMT) and press RETURN.
Do you want to configure the LRU software for line SMT [y/n]:
● Enter
y
and press RETURN.
The line is configured.
A list containing the allocations of the time zone settings is displayed ("Timezone-Configuration").
Select a timezone [1-12]:
● Enter number of time zone desired and confirm by pressing RETURN.
Now the language to be used by the LC system when it is started up can be selected ("Language-
Configuration").
(1) D = Deutsch (German) 2) F = French 3) GB = English 4) I = Italian )
Enter a value in between [1-4]:
● Enter number of language desired and confirm by pressing RETURN.

1 Hardware / Software Installation User Manual Line Computer UNIX
1.2 Software Installation Software Version 501.xx 01/99 Issue
1 - 12
NOTE
Only in cases where a second LAN card for the SIPLACE LAN is installed in the line computer, will
the IP address, netmask and broadcast address of the LAN card for the SIPLACE LAN be displayed
together with an inquiry as to whether they are to be changed.
● Enter
y
and press RETURN if the data are to be changed.
Enter internet address for SIPLACE network card
(<Return> for default....):
● Enter the address and press RETURN.
The entry is displayed.
Is the internet address ’...’ correct [y/n]:
● Enter
y
and press RETURN if the entry is correct.
(Enter
n
and press RETURN if the entry needs to be corrected).
Enter netmask for SIPLACE network card
(<Return> for default....):
● Enter the number of the "netmask" and press RETURN.
The entry is displayed.
Is the netmask ’...’ correct [y/n]:
● Enter
y
and press RETURN if the entry is correct.
(Enter
n
and press RETURN if the entry needs to be corrected).
Enter broadcast address for SIPLACE network card
(<Return> for default....):
● Enter the number of the "broadcast address" and press RETURN.
The entry is displayed.
Is the broadcast address ’...’ correct [y/n]:
● Enter
y
and press RETURN if the entry is correct.
(Enter
n
and press RETURN if the entry needs to be corrected).
The entry of
y
completes the configuration of the LAN card.