13 Production Tools / Set-Up User Manu al Line Computer UNIX 13.1 Set-Up Editor (Feeder Part and W PC Editors) Software Version 501.xx 01/99 Issue 13 - 24 Fig. 13.1.18 Diagonal in X- Direction and Y- Direction NOT E If o…

100%1 / 621
User Manual Line Computer UNIX 13 Production Tools / Set-Up
Software Version 501.xx 01/99 Issue 13.1 Set-Up Editor (Feeder Part and WPC Editors)
13 - 23
Fig. 13.1.16 Pick-Up Height: Offset in Z-Direction
-
Pick-up ang. [degr]
Pick-up angle (rotational angle) of the component in the tray compartment (division) (default value:
0.00). See Fig. 13.1.17.
Fig. 13.1.17 Pick-Up Angle of the Component in the Compartment of the Waffle-Pack Tray
-
Diagonal X [mm]
Offset from the center of the first compartment (division) to the center of the last compartment in
x-direction (default value: 0.000). See Fig. 13.1.18.
-
Diagonal Y [mm]
Offset from the center of the first compartment to the last compartment in y-direction (default value:
0.000). See Fig. 13.1.18.
pick-up hei
g
ht
Z
(
mm
)
component
pick-up an
g
le
[
de
g
ree
]
compartment of
waffle-pack tra
y
waffle-pack tra
y
waffle-pack
tra
y
carrier
13 Production Tools / Set-Up User Manual Line Computer UNIX
13.1 Set-Up Editor (Feeder Part and WPC Editors) Software Version 501.xx 01/99 Issue
13 - 24
Fig. 13.1.18 Diagonal in X- Direction and Y-Direction
NOTE
If offset values were entered that are not valid for the selected feeder type, the respective editing fields are
surrounded by a red frame. The invalid values must first be corrected before all values can be accepted.
center of last compartment
center of
first compart-
dia
g
onal X
[
mm
]
dia
g
onal
Y
[
mm
]
compartment
of waffle-
pack tra
y
waffle-pack
tra
y
carrier
ment
User Manual Line Computer UNIX 13 Production Tools / Set-Up
Software Version 501.xx 01/99 Issue 13.1 Set-Up Editor (Feeder Part and WPC Editors)
13 - 25
13.1.3.6 Nozzle Changer / Machine Options Editor
Clicking on the "Nozzle Changer" option on the SERVICES menu causes the window "Machine Options
Editor" to be opened (see Fig. 13.1.19).
The Nozzle Changer can be configured with the required nozzles for a given set-up in the Machine Options
Editor. The nozzles are allocated to the individual locations (divisions) of the Nozzle Changer. Within a Nozzle
Changer nozzles can be moved or deleted. This allocation can be changed at any time as required.
The Machine Options Editor can also be invoked upon setting up the station configuration in order to permanently
assign particular nozzles to given locations (divisions). This allocation can only be changed there.
If nozzles were assigned to given locations in the nozzle changer in Station Configuration, they are displayed
upon opening the Machine Options Editor. These locations cannot be changed in the Feeder Part Editor.
Fig. 13.1.19 Machine Options Editor
The Machine Options Editor is subdivided into the following areas:
-
Menu bar
-
Identification field
-
Command area
-
Selection field "Divisions"
-
Selection field "Nozzle"
menu bar identification field
selection field
"Nozzle"
command
selection field
"Divisions"
area