00191413-01.pdf - 第584页

17.4 Set-Up Generation User Manual Line Computer UNIX 17.4.1 Lot Handlin g Software Version 501.xx 01/99 Issue 17 - 52 FILE Save FIL E Quit 17.4 Set-Up Generation A common set-up is to be c reated fo r the thr ee PCBs. 1…

100%1 / 621
User Manual Line Computer UNIX 17.3 Description of Components and PCBs
Software Version 501.xx 01/99 Issue 17.3.3 PCB 3: Focus on Cluster Technique
17 - 51
Entering placement positions:
the entr
y
of placement positions is dispensed with for the duplicate.
To save the PCB data, proceed as follows:
87. In the PCB Editor click on the
Save
option on the
FILE
menu.
The PCB data are saved.
88. Click on the
Quit
option on the
FILE
menu.
The PCB Editor is closed. The description of PCB 3 is completed.
Have you entered all values correctly? Compare the solutions below (see also Fig. 17.3.7 on
page 17-41):
Di
mens
i
ons o
f
th
e
PCB
(
page
17
-
43
)
Vector (0.0) -->
Corner_1:
Vector Corner_1 -->
Corner_2
PCB height
PP position
recognition
Ink spot
PCB
position
recognition
X Y X Y h
-5 -5 335 272 1.5 no no no
Offset values of the first cluster (page 17-45)
X Y
Angle
10 10 0
Dimensions of the first cluster (page 17-45)
Vector (0,0) -->
Corner_1:
Vector Corner_1 -->
Corner_2
PCB height
PP position
recognition
Ink spot
PCB
position
recognition
X Y X Y h
0 0 150 116 no no yes
Offset values of the first single circuit (page 17-47)
X Y
Angle
15 15 0
Offset values of the duplicated single circuits (page 17-49)
Single circuit X Y ] Angle
board_2 60 15 0
baord_3 105 15 0
Offset values of the duplicated clusters (page 17-49)
Cluster X Y Angle
pattern_2 165 10 0
pattern_3 160 252 180
pattern_4 315 252 180
17.4 Set-Up Generation User Manual Line Computer UNIX
17.4.1 Lot Handlin
g
Software Version 501.xx 01/99 Issue
17 - 52
FILE
Save
FILE
Quit
17.4 Set-Up Generation
A common set-up is to be created for the three PCBs.
17.4.1 Lot Handling
Opening the
optimization dialog
Creating lot file
Editing lot file
Generating basic
optimization data
Saving lot file
User Manual Line Computer UNIX 17.4 Set-Up Generation
Software Version 501.xx 01/99 Issue 17.4.1 Lot Handlin
g
17 - 53
To open the optimization dialog, proceed as follows:
1. Click on the Optimization dialo
g
icon .
The optimization dialo
g
is opened.
To create a lot file, proceed as follows:
2. Activate the Create icon .
A window is opened.
3. Click on the editin
g
field and enter a name for the lot file
,
here:
Examples.lose
.
4. Click on the
OK
button.
Job Control is opened.
To edit a lot file, proceed as follows:
5. In Job Control activate the Create icon , then activate the Edit support
icon .
The Edit support Lot Data is opened.
6. Select the PCB
y
ou wish to edit b
y
double-clickin
g
, here:
Example_1.la
.
The PCB is transferred to the
Selection:
field.
7. Click on the
Abort
button, the other data are not used at this point.
Edit support is closed. The selected PCB is transferred to the editin
g
area.
8. In the editin
g
area click on the
Lot name
field and enter the lot name, here:
ex1
.
9. In the editin
g
area click on the
Lot size
field and enter the lot size, here:
10
.
10. In the editin
g
area click on the
Lot type
field and enter the lot t
y
pe, here:
F
.
11. Click on the
OK
button.
The
j
ob is transferred to the lot file. In the case of fault
y
entries, the respective field is surrounded b
y
a red
frame and an error messa
g
e is displa
y
ed above the list. Correct the entr
y
.
12. Insert the remainin
g
PCBs analo
g
ousl
y
, here:
Example_2.la
and
Example_3.la
, see chart.
To create the basic optimization data, proceed as follows:
13. Click on the
Basic Optimization Data...
command on the
SERVICES
menu.
The Basic optimization data window is opened.
14. Activate the Create icon and then activate the Edit support icon .
The Edit support Basic Optimization Data is opened.
15. Select the line,
here:
SMT.AK,
and the subline
,
here:
Linie.VA,
b
y
double-clickin
g
.
16. Click on the
Abort
button, no fixed or initial set-ups are used here. The edit support is closed.
The selected data are transferred to the editin
g
area.
17. Click on the
OK
button.
The data are transferred to the list.
18. Click on the
Quit
command on the
FILE
Menu.
A dialo
g
box containin
g
a re
q
uest for savin
g
data is opened
19. Click on the
Yes
button.
The Basic optimization data window is closed, the data are saved.
To save the lot file, proceed as follows:
20. Click on the
Save
command on the
FILE
menu.
The lot file is saved in the Job Data under the entered name.
21. Click on the
Quit
command on the
FILE
menu.
Job Control is closed. The Optimization Dialo
g
is opened.
PCB Lot name Lot size
Lot
type
Example_1.la ex1 10 F
Example_2.la ex2 13 F
Example_2.la ex3 16 F