00191413-01.pdf - 第467页

User Manual Line Computer UNIX 14 Control / Control Modules Software Version 501.xx 01/99 Issue 14.2 Line Control 14 - 31 NOTE The conveyor width can only be adjuste d in increm ents of 1/1 0 mm so that only the first di…

100%1 / 621
14 Control / Control Modules User Manual Line Computer UNIX
14.2 Line Control Software Version 501.xx 01/99 Issue
14 - 30
- Start/Stop of the Line
The Start or Stop button is used to start or stop, respectively, the line. If start/stop of the line is activa-
ted, it automatically causes all sublines to be started/stopped, too.
Click on appropriate button Start or Stop.
- Blocking/unblocking of all input conveyors
The block/unblock button is used to block or unblock, respectively, all input conveyors forming part of
the sublines of the complete line.
Click on appropriate button Block or Unblock.
14.2.3.3 Subline
Display and editing fields of the subline (right portion of main window):
- Name
Here, the name of the current subline is displayed (see Fig. 14.2.1).
- Changing the current Subline
The selection field (below the name of the current subline) contains a listing of all sublines forming
part of the overall line..
Select desired subline in the selection field by clicking.
The name of this system is now displayed as the current Subline.
NOTE
Any change of the "current" subline will automatically cause the selected UFO strategy to be updated.
- Editing the conveyor width
Click on the Conveyor width button.
The dialog box for entering the conveyor width is opened.
Enter the new width in the Conveyor width editing field.
User Manual Line Computer UNIX 14 Control / Control Modules
Software Version 501.xx 01/99 Issue 14.2 Line Control
14 - 31
NOTE
The conveyor width can only be adjusted in increments of 1/10 mm so that only the first digit after the
decimal point of the entered value will be taken into account.
In the case of a standard single conveyor, the value for the new width is entered in the "Conveyor
width (track 1)" editing field.
In the case of a dual conveyor, the "Conveyor width (track 1)" editing field applies to the right
conveyor lane, and the "Conveyor width (track 2)" editing field to the left conveyor lane.
Different widths can be set for the two conveyor lanes of a dual conveyor.
If the Width adj. upon cluster change button is activated, deactivate the same by clicking on it.
Click on OK in the dialog box for the data to be accepted.
A dialog box containing the query "Is line xx empty?" appears.
If the line is empty, click on OK.
The new conveyor width is passed on to the Line Control thus activating the width adjustment
mechanism. (Clicking on "Abort" causes the action to be aborted).
- Activating the Width Adjustment Upon Cluster Change
The automatic adjustment of the required conveyor width upon changing over to a new PCB type can
be activated by means of a button contained in the "Conveyor width" dialog box (see above).
Click on the Width adj. upon cluster change button.
NOTE
The required conveyor width is read in from the cluster data of the new PCB type and is auto-mati-
cally adjusted by means of the width adjustment function.
When changing over to the barcode operating mode, the "Width adj. upon cluster change" button
must be deactivated.
Click on OK in the dialog box for the data to be accepted.
(When "Cancel" is clicked on, the action is aborted).
- Set UFO strategy for the current subline
You can select between the UFO strategies "Pass-through" and "Remove".
Click on the button next to the desired "strategy"..
If the "Pass-through" option is selected, the "UFO PCB" (see description in section 14.2.1) is
conveyed through the line without being processed and must be removed at the end of the line.
If the "Remove" option is selected the PCB must be removed at the end of the station.
NOTE
Only when the button Data transfer is clicked on will the new UFO strategy data be sent to the Line
control.
14 Control / Control Modules User Manual Line Computer UNIX
14.2 Line Control Software Version 501.xx 01/99 Issue
14 - 32
- Entering Data
Refer to the description for the line (page 14 - 29).
- Start/Stop of Subline
The Start or Stop button is used to start or stop, respectively, the current subline.
Click on appropriate button Start or Stop.
- Blocking/Unblocking of input conveyor
The Block or Unblock button is used to block or unblock, respectively, the input conveyor of the cur-
rent subline.
Click on Block or Unblock button.