00191413-01.pdf - 第487页
User Manual Line Computer UNIX 14 Control / Control Modules Software Version 501.xx 01/99 Issue 14.4 Set-Up Modification Generator 14 - 51 ● Clic k on bu tton Set-up not modified . A dialog box con tainin g the fol lowin…

14 Control / Control Modules User Manual Line Computer UNIX
14.4 Set-Up Modification Generator Software Version 501.xx 01/99 Issue
14 - 50
NOTE
If during the creation of changeover instructions for a PCB-specific set-up one realizes that certain set-up
elements (e.g. components) are missing in the selected target set-up, an error message is displayed for each
of the missing elements.
Fig. 14.4.3 Display of Changeover Instructions for the Station "SIPLACE_2"
- Set-up not modified
NOTE
This button can only
be selected when the Set-Up Modification Generator was opened by a station
controller (initiated by a requesting program).
The operator clicks on this button when he was not able to physically modify the selected station for
any reason.
message line display area

User Manual Line Computer UNIX 14 Control / Control Modules
Software Version 501.xx 01/99 Issue 14.4 Set-Up Modification Generator
14 - 51
● Click on button Set-up not modified.
A dialog box containing the following warning message is displayed:
● Confirm the dialog box with Ok.
NOTE
If the set-up of only one station of the subline could not be changed over, it is not possible to produce
any PCB type on the entire subline for which the follow-up set-up displayed has been specified in the
job data for the production of this PCB type.
- Set-up modified
NOTE
This button can only
be selected when the Set-Up Modification Generator was opened by a station
controller (initated by a requesting program).
This enables the operator to confirm the physical set-up changeover of a station.
This button is clicked on whenever a station selected from the selection field "Stations" has been reset
in accordance with the corresponding changeover instructions.
● Click on button Set-up modified.
If no station was selected, a corresponding prompt requesting the selection of a station is dis-
played, otherwise the following dialog box is opened:
● Confirm the dialog box with Ok.
The dialog box is closed and the station where set-up changeover has been completed (confir-
med) is no longer displayed in the selection field "Stations".
NOTE
When the set-up of all
stations of the subline has been changed over and when the completed chan-
geover has been confirmed for each station, the Set-Up Modification Generator is automatically closed.
It is not
possible to prematurely close the Set-Up Modification Generator via the menu using menu
option Quit!
14 Control / Control Modules User Manual Line Computer UNIX
14.4 Set-Up Modification Generator Software Version 501.xx 01/99 Issue
14 - 52