00191413-01.pdf - 第479页

User Manual Line Computer UNIX 14 Control / Control Modules Software Version 501.xx 01/99 Issue 14.4 Set-Up Modification Generator 14 - 43 ● Click on overwrite when the data are to be overwritt en. Or el se, ● click on d…

100%1 / 621
14 Control / Control Modules User Manual Line Computer UNIX
14.4 Set-Up Modification Generator Software Version 501.xx 01/99 Issue
14 - 42
Select target set-up "xx.AR" by double-clicking.
Open the directory "*master data:Anlagen:xx.ak:xx.va" by double-clicking.
All existing follow-up set-ups are now displayed in the FSB.
Enter name xx.ar for the new follow-up set-up to be created and confirm with OK, or select
existing follow-up set-up by double-clicking.
NOTE
When the setting with confirmation has been selected (see section 14.4.3.1) and an
existing follow-up set-up is selected, the following dialog box is displayed:
User Manual Line Computer UNIX 14 Control / Control Modules
Software Version 501.xx 01/99 Issue 14.4 Set-Up Modification Generator
14 - 43
Click on overwrite when the data are to be overwritten.
Or else,
click on do not overwrite when the data are not to be overwritten.
Enter new name xx.ar for the follow-up set-up in the FSB and confirm with OK.
The FSB is closed and the main window of the Set-Up Modification Generator is displayed on the
screen.
- Set-up --> Set-up
This option enables the user to obtain instructions for the changeover from an initial set-up to be
specified (selected) to a follow-up set-up that must likewise be specified (selected).
Click on button Set-up --> Set-up.
The selection window is closed and the main window of the Set-Up Modification Generator toge-
ther with the FSB for the selection of the follow-up set-up, which is located above it, is opened.
Successively select line "*xx.ak" and subline "*xx.va" by double-clicking.
Select follow-up set-up "xx.ar" from the FSB (see example on page 14 - 41) by double-clicking.
In the FSB a prompt requesting the selection of an initial set-up is now displayed.
Open the directory "*master data:Anlagen:xx.ak" by double-clicking.
Successively select subline "*xx.va" and initial set-up "xx.ar" by double-clicking.
The FSB is closed and the main window of the Set-Up Modification Generator is displayed on the
screen.
- Set-up --> PCB-specific set-up
This option enables the operator to obtain instructions for the changeover from an initial set-up to be
specified (selected) to a follow-up set-up for the production of a specific PCB type.
Click on button Set-up --> PCB-specific set-up.
The selection window is closed and the main window of the Set-Up Modification Generator
together with the FSB for the selection of the target set-up, which is located above it, is opened.
(see example on page 14 - 42).
Successively select PCB "*xx.la", "*.ad", line "*xx.AK" and subline "*xx.VA" by double-clicking.
The FSB now displays a list of possible target set-ups.
Select set-up "xx.AR" which is to serve as default set-up for the target set-up, by double-clicking.
In the FSB a prompt requesting the selection of an initial set-up is now displayed.
Open the directory "*master data:Anlagen:xx.ak" by double-clicking.
Successively select subline "*xx.va" and initial set-up "*xx.ar" by double-clicking.
Open the directory "*master data:Anlagen:xx.ak:xx.va" by double-clicking.
All previously defined set-ups are displayed in the FSB (see example on page 14 - 41).
Enter name xx.ar for the new follow-up set-up to be created and confirm with OK, or select
existing follow-up set-up by double-clicking.
The FSB is closed and the main window of the Set-Up Modification Generator is displayed on the
screen.
14 Control / Control Modules User Manual Line Computer UNIX
14.4 Set-Up Modification Generator Software Version 501.xx 01/99 Issue
14 - 44
- Display set-up
This option enables the operator to have a selected set-up displayed and printed out, if necessary.
Click on button Display set-up.
The selection window is closed and the main window of the Set-Up Modification Generator
together with the FSB for the selection of the set-up, which is located above it, is opened.
Successively select line "*xx.ak" and subline "*xx.va" by double-clicking.
All previously defined set-ups are displayed in the FSB.
Select set-up "xx.ar" by double-clicking.
The FSB is closed and the main window of the Set-Up Modification Generator is displayed on the
screen. In the display area of the main window (see Fig. 14.4.2) the set-up for the station selected
from the selection field "Stations" is displayed.
- Display PCB-specific part of set-up
This option enables the operator to display the set-up for a given PCB type and print it out, if
necessary.
Click on button Display PCB-specific part of set-up.
The selection window is closed and the main window of the Set-Up Modification Generator
together with the FSB for the selection of the PCB, which is located above it, is opened.
Successively select the PCB "*xx.la", "*.ad", line "*xx.AK" and subline "*xx.VA" by double-clicking.
A list of the set-ups that can be chosen for the selected PCB type is displayed in the FSB.