00191413-01.pdf - 第479页
User Manual Line Computer UNIX 14 Control / Control Modules Software Version 501.xx 01/99 Issue 14.4 Set-Up Modification Generator 14 - 43 ● Click on overwrite when the data are to be overwritt en. Or el se, ● click on d…

14 Control / Control Modules User Manual Line Computer UNIX
14.4 Set-Up Modification Generator Software Version 501.xx 01/99 Issue
14 - 42
● Select target set-up "xx.AR" by double-clicking.
● Open the directory "*master data:Anlagen:xx.ak:xx.va" by double-clicking.
All existing follow-up set-ups are now displayed in the FSB.
● Enter name xx.ar for the new follow-up set-up to be created and confirm with OK, or select
existing follow-up set-up by double-clicking.
NOTE
When the setting with confirmation has been selected (see section 14.4.3.1) and an
existing follow-up set-up is selected, the following dialog box is displayed:
User Manual Line Computer UNIX 14 Control / Control Modules
Software Version 501.xx 01/99 Issue 14.4 Set-Up Modification Generator
14 - 43
● Click on overwrite when the data are to be overwritten.
Or else,
● click on do not overwrite when the data are not to be overwritten.
● Enter new name xx.ar for the follow-up set-up in the FSB and confirm with OK.
The FSB is closed and the main window of the Set-Up Modification Generator is displayed on the
screen.
- Set-up --> Set-up
This option enables the user to obtain instructions for the changeover from an initial set-up to be
specified (selected) to a follow-up set-up that must likewise be specified (selected).
● Click on button Set-up --> Set-up.
The selection window is closed and the main window of the Set-Up Modification Generator toge-
ther with the FSB for the selection of the follow-up set-up, which is located above it, is opened.
● Successively select line "*xx.ak" and subline "*xx.va" by double-clicking.
● Select follow-up set-up "xx.ar" from the FSB (see example on page 14 - 41) by double-clicking.
In the FSB a prompt requesting the selection of an initial set-up is now displayed.
● Open the directory "*master data:Anlagen:xx.ak" by double-clicking.
● Successively select subline "*xx.va" and initial set-up "xx.ar" by double-clicking.
The FSB is closed and the main window of the Set-Up Modification Generator is displayed on the
screen.
- Set-up --> PCB-specific set-up
This option enables the operator to obtain instructions for the changeover from an initial set-up to be
specified (selected) to a follow-up set-up for the production of a specific PCB type.
● Click on button Set-up --> PCB-specific set-up.
The selection window is closed and the main window of the Set-Up Modification Generator
together with the FSB for the selection of the target set-up, which is located above it, is opened.
(see example on page 14 - 42).
● Successively select PCB "*xx.la", "*.ad", line "*xx.AK" and subline "*xx.VA" by double-clicking.
The FSB now displays a list of possible target set-ups.
● Select set-up "xx.AR" which is to serve as default set-up for the target set-up, by double-clicking.
In the FSB a prompt requesting the selection of an initial set-up is now displayed.
● Open the directory "*master data:Anlagen:xx.ak" by double-clicking.
● Successively select subline "*xx.va" and initial set-up "*xx.ar" by double-clicking.
● Open the directory "*master data:Anlagen:xx.ak:xx.va" by double-clicking.
All previously defined set-ups are displayed in the FSB (see example on page 14 - 41).
● Enter name xx.ar for the new follow-up set-up to be created and confirm with OK, or select
existing follow-up set-up by double-clicking.
The FSB is closed and the main window of the Set-Up Modification Generator is displayed on the
screen.

14 Control / Control Modules User Manual Line Computer UNIX
14.4 Set-Up Modification Generator Software Version 501.xx 01/99 Issue
14 - 44
- Display set-up
This option enables the operator to have a selected set-up displayed and printed out, if necessary.
● Click on button Display set-up.
The selection window is closed and the main window of the Set-Up Modification Generator
together with the FSB for the selection of the set-up, which is located above it, is opened.
● Successively select line "*xx.ak" and subline "*xx.va" by double-clicking.
All previously defined set-ups are displayed in the FSB.
● Select set-up "xx.ar" by double-clicking.
The FSB is closed and the main window of the Set-Up Modification Generator is displayed on the
screen. In the display area of the main window (see Fig. 14.4.2) the set-up for the station selected
from the selection field "Stations" is displayed.
- Display PCB-specific part of set-up
This option enables the operator to display the set-up for a given PCB type and print it out, if
necessary.
● Click on button Display PCB-specific part of set-up.
The selection window is closed and the main window of the Set-Up Modification Generator
together with the FSB for the selection of the PCB, which is located above it, is opened.
● Successively select the PCB "*xx.la", "*.ad", line "*xx.AK" and subline "*xx.VA" by double-clicking.
A list of the set-ups that can be chosen for the selected PCB type is displayed in the FSB.