00191413-01.pdf - 第587页

User Manual Line Computer UNIX 17.4 Set-Up Generation Software Version 501.xx 01/99 Issue 17.4.2 Automatic Set-Up Generation 17 - 5 5 To start Optimization for a lot file, pr oceed as follows: 1. In the Opti mization Dia…

100%1 / 621
17.4 Set-Up Generation User Manual Line Computer UNIX
17.4.2 Automatic Set-Up Generation Software Version 501.xx 01/99 Issue
17 - 54
17.4.2 Automatic Set-Up Generation
Starting Optimization
for lot file
Starting Producibility
check for lot file
Printing optimized
set-up
User Manual Line Computer UNIX 17.4 Set-Up Generation
Software Version 501.xx 01/99 Issue 17.4.2 Automatic Set-Up Generation
17 - 55
To start Optimization for a lot file, proceed as follows:
1. In the Optimization Dialo
g
activate the
Read in directory
icon .
The new lot file is listed.
2. Activate the Start icon .
3. Click on the
Examples.lose
lot file.
Optimization of the lot file is started. The Info Box indicates the pro
g
ress and the phases of the process,
as well as production time and the chan
g
eover time of the set-ups bein
g
calculated.
Upon the successful optimization, the status of the lot file is indicated as
optimized
. The set-up name
here:
Examples01.ar
is automaticall
y
assi
g
ned to the optimized set-up.
If errors are encountered durin
g
Optimization, the optimization run is aborted and the status of the lot file
is indicated as
faulty
. In the case of an error, proceed as follows:
Activate the Select icon .
Click on the fault
y
j
ob.
Click on the
View error file
option on the
SERVICES
menu.
The File displa
y
containin
g
the error file is opened.
Correct the errors displa
y
ed.
Click on the
Quit
option on the
FILE
menu.
File displa
y
is closed.
Optimization is re-started.
To check the producibility of a lot file:
4. Activate the Select icon .
5. Click on the
Examples.lose
lot file.
6. Click on the
Producibility check
option on the
SERVICES
menu.
The producibilit
y
check is started. Upon the successful check, the status of the
j
obs is indicated as
R (=ready)
.
To obtain a printout of the optimized set-up, proceed as follows:
7. Click on the
Examples.lose
lot file.
8. Click on one of the
j
obs of this lot file.
9. Click on the
Display set-up
option on the
SERVICES
menu.
The Set-Up Modification Generator is opened.
10. In the Set-Up Modification Generator activate the
Set-up modification instructions
button.
The set-up chan
g
eover instructions are displa
y
ed.
11. On the
FILE
menu click on the
Print
command, then
Print Line
.
The set-up is printed out for all stations.
12. Click on the
Quit
option on the
FILE
menu.
The Set-Up Modification Generator is closed.
13. After optimization has been successfull
y
completed, click on the
Quit
option on the
FILE
menu.
The Optimization Dialo
g
is closed.
17.4 Set-Up Generation User Manual Line Computer UNIX
17.4.3 Manual Set-Up Adjustment Software Version 501.xx 01/99 Issue
17 - 56
17.4.3 Manual Set-Up Adjustment
The packa
g
in
g
form for component Comp6 is to be chan
g
ed: it is supplied in stick ma
g
azines. Comp5 is addi-
tionall
y
supplied in waffle-pack tra
y
s. The set up is adapted manuall
y
.
Opening Set-up Edi-
tor/Feeder Part Editor
continued on pa
g
e 17-58
Deleting feeders
Allocating feeder to a
track
Setting up feeders
Allocating component
to a feeder