FlexTRAK OH Material Handler Manual.pdf - 第261页

© 2023 Nordson C orporation 8-1 8 Specif ications 8.1 Overview Facility requi rements and sp ecifications are listed in this section . All facility power sou rces must be safel y grounded. Me eting the requir ements wi l…

100%1 / 272
© 2023 Nordson Corporation 8-1
8 Specifications
8.1 Overview
Facility requirements and specifications are listed in this section. All facility power sources must be safely
grounded. Meeting the requirements will ensure reliable operation and safety of the dispensing system.
This section covers the following topics:
Facility Requirements
System Dimensions
Clearance Distance Requirement
System Block Diagram
Pneumatic Diagrams
WARNING! To ensure optimal performance and safety, it is necessary to install the
dispensing system in a facility that meets the requirements listed in this section.
Failure to meet these requirements could cause serious bodily harm to the user
and serious damage to the dispensing system. If you have any questions, please
contact March for additional information.
8.2 Safety First
Operation of your FlexTRAK-OH Material Handler involves mechanical devices, air pressure, and
electrical power. It is essential that every person servicing or operating the FlexTRAK-OH fully
understands all hazards, risks, and safety precautions. When properly operated and maintained, the
FlexTRAK-OH Material Handler should be safe and reliable. Refer to Section 2 - Safety before
installation, operation, or servicing the machine
.
FlexTRAK-OH Material Handling System IOM Manual Specifications
8-2 © 2023 Nordson Corporation
8.3 Facility Requirements
To ensure optimal performance and safety, install the FlexTRAK-OH in a facility that meets or exceeds
the requirements listed in following sections. All facility power sources must be safely grounded.
8.3.1 Electrical
WARNING! Failure to obey the requirements may cause serious human injuries and machine
damages.
Table 8-1 Electrical Specifications
Properties Specification Value
Electrical supply
value into machine
isolator switch
Operating Voltage 220/240 VAC ± 10%
Phase 1 phase
Frequency
50 / 60 Hz
Power Cable
Cable Size
Rated Voltage
Ambient Temperature
Live (x1), Neutral (x1), Ground (x1)
8 AWG, 10 mm
220/240 V
16˚C @ 60.8˚F
Machine electrical
system design
parameters
Full Load Current 27.8 A
Largest Motor Current
0.3 A
Short Circuit Current Rating
(SCCR)
10k A
Drawing Document
Name FLEXTRAK-SHS LDR & UNLDR CNVYR ELECTRICAL SCHEMATICS
Number
NM001-CD
8.3.2 Energy Consumption
Table 8-2 Energy Consumption
Usage Condition
Value (kW)
Idle
0.33
Average
1.92
Peak 2.08