FlexTRAK OH Material Handler Manual.pdf - 第263页
FlexTRAK-OH Material Handli ng System IOM Manual Specifications © 2023 Nordson C orporation 8-3 8.3.3 Pneumatic Properties Specification Value Air preparation unit Incoming air pressure 6 bar (maxim um) Incoming air tubi…

FlexTRAK-OH Material Handling System IOM Manual Specifications
8-2 © 2023 Nordson Corporation
8.3 Facility Requirements
To ensure optimal performance and safety, install the FlexTRAK-OH in a facility that meets or exceeds
the requirements listed in following sections. All facility power sources must be safely grounded.
8.3.1 Electrical
WARNING! Failure to obey the requirements may cause serious human injuries and machine
damages.
Table 8-1 Electrical Specifications
Properties Specification Value
Electrical supply
value into machine
isolator switch
Operating Voltage 220/240 VAC ± 10%
Phase 1 phase
Frequency
50 / 60 Hz
Power Cable
Cable Size
Rated Voltage
Ambient Temperature
Live (x1), Neutral (x1), Ground (x1)
8 AWG, 10 mm
220/240 V
16˚C @ 60.8˚F
Machine electrical
system design
parameters
Full Load Current 27.8 A
Largest Motor Current
0.3 A
Short Circuit Current Rating
(SCCR)
10k A
Drawing Document
Name FLEXTRAK-SHS LDR & UNLDR CNVYR ELECTRICAL SCHEMATICS
Number
NM001-CD
8.3.2 Energy Consumption
Table 8-2 Energy Consumption
Usage Condition
Value (kW)
Idle
0.33
Average
1.92
Peak 2.08

FlexTRAK-OH Material Handling System IOM Manual Specifications
© 2023 Nordson Corporation 8-3
8.3.3 Pneumatic
Properties Specification Value
Air preparation unit
Incoming air pressure 6 bar (maximum)
Incoming air tubing size 10 mm
Operating air pressure 5.5 bar
Drawing Document
Name FLEXTRAK-SHS-PNEUMATIC
Number A100.06.00.0000
8.3.4 Environment
Properties Value
Operating temperature 17˚C to 50˚C (62.6˚F to 122˚F)
Transportation and storage temperature -40˚C to 50˚C (-40˚F to 122˚F)
Operating environment quality
Cleanroom:
Class 10K
Class 1000 (optional)
Operating altitude 1000 m (maximum)
Relative humidity (amount of water vapor
present in the air)
30% to 50%

FlexTRAK-OH Material Handling System IOM Manual Specifications
8-4 © 2023 Nordson Corporation
8.4 System Dimensions
8.4.1 Front View
Measurement unit: mm
Figure 8-1 Front View Dimensions