FlexTRAK OH Material Handler Manual.pdf - 第91页

FlexTRAK-OH Material Handli ng System IOM Manual Material Handler Operation © 2023 Nordson C orporation 4-3 4. Plug the pendant socke t into the intende d MHS mac hine pendant input port ( Figure 4-2) . 5. Secure the con…

100%1 / 272
FlexTRAK-OH Material Handling System IOM Manual Material Handler Operation
4-2 © 2023 Nordson Corporation
4.4 Using the Mobile Control Pendant
The FlexTRAK-OH Material Handling System (MHS) uses the mobile control pendant to perform all
local machine manual triggering activities, such as:
Strip lane conversion
Configuration of module/station axis motor control parameters
Troubleshooting
Other service or maintenance activities
Figure 4-1 Material Handling System (MHS) Mobile Control Pendant HMI
4.4.1 Pendant Setup
The mobile control pendant storage compartment is in machine front access panel (Figure 1-1).
WARNING! Ensure the machine is off before performing pendant setup.
To setup the pendant:
1. Unlock and open the machine front access panel and remove the pendant from the storage
compartment.
2. Locate the machine communication ports for the mobile control pendant cable connection.
3. Select the communication port that allows the user and pendant to maneuver around the
machine module/station.
NOTE
The length of the pendant cable is 5 meters.
FlexTRAK-OH Material Handling System IOM Manual Material Handler Operation
© 2023 Nordson Corporation 4-3
4. Plug the pendant socket into the intended MHS machine pendant input port (Figure 4-2).
5. Secure the connection by turning the locking ring.
Figure 4-2 Pendant Setup
4.5 User Access Login and Logout
The FlexTRAK OH software automatically starts when the machine is powered on.
To login to the system:
1. To exit from current user account, press the
LOGOUT on bottom right of home screen.
The user access login screen will display (Figure 4-3).
Figure 4-3 User Access Login Screen
2. Enter the user name and press enter on the screen keypad.
3. Enter the password and press enter on the screen keypad.
The default user name and password is listed below:
- User Name: ADM
- Password: 111111
4. Press
Login when done.
FlexTRAK-OH Material Handling System IOM Manual Material Handler Operation
4-4 © 2023 Nordson Corporation
4.6 HMI Data Input/Output Indicators
4.6.1 HMI Data Input Indicators
The HMI input buttons input data to the machine logic controller. Each label on the button describes its
function. Some buttons use a pictogram/symbol rather than text to describe their functions. See Table 4-1
through Table 4-3 for detailed descriptions of the HMI Data Input buttons.
4.6.1.1 Screen Navigation Buttons
Table 4-1 Screen Navigation Buttons
Button Description
Shows the machine HMI screen as labeled on the button text.
Some screens have multiple pages in order to show all
available features and indicators.
Select to move to the next screen or to move to
previous screen.
Scrolls the page up/down.
4.6.1.2 Control Switches
Table 4-2 Control Switches
Button Description
Triggers the function labeled on the button text.
Enables (unlocks) or disables (locks) the motor actuation
switch to jog the axis.
Enables (ON) or disables (OFF) a specific component function.
4.6.1.3 Data Selection and Update Forms
Table 4-3 Data Selection and Update Forms
HMI Object Description
When pressed, the HMI keypad displays so you can
insert a specific decimal value (Example: 1, 20, 300, 000)
for the form function. The data value type is labeled
beside the form.
Click the down arrow to list all available parameters
related to the current screen.