FlexTRAK OH Material Handler Manual.pdf - 第57页
FlexTRAK-OH Material Handli ng System IOM Manual Installation © 2023 Nordson C orporation 3-7 2. Follo w the steps below to rem ove strip claw 1 and st rip claw 2 . Refer to the item letters in ( Figure 3-8) to perform t…

FlexTRAK-OH Material Handling System IOM Manual Installation
3-6 © 2023 Nordson Corporation
3.7 Setup Procedures
Tools and Materials Needed
• Strip claw set for claw 1 and claw 2
• Strip lane set for strip loading, plasma chamber, and strip unloading
NOTE Each kit part is labeled with the dedicated Kit ID (Kit ID: width x lane quantity). Ensure
the Kit ID assembly groups are correct before proceeding to production or maintenance
mode.
CAUTION! Ensure the machine is in idle mode by verifying that the light tower status light is
solid yellow (Figure 2-12). Ensure all previously handled workpieces (magazine
and strip) are removed from the machine platform.
3.7.1 Conversion Kit Replacement
1. Open the front sliding doors to access the machine interior components (Figure 3-7).
Figure 3-7 Open Front Sliding Doors

FlexTRAK-OH Material Handling System IOM Manual Installation
© 2023 Nordson Corporation 3-7
2. Follow the steps below to remove strip claw 1 and strip claw 2. Refer to the item letters in
(Figure 3-8) to perform this procedure.
a. Ensure (A) the claw kit is positioned either at left (loading area) or right side (unloading
area).
b. Safely remove the circular containers (C) and (E) (Figure 3-9).
Item
Name
A X-axis Actuator (transfer motor)
B Strip Claw 1
C Claw 1 Circular Connector
D Strip Claw 2
E Claw 2 Circular Connector
Figure 3-8 Strip Transfer Claw Module Components
Figure 3-9 Remove Circular Connectors

FlexTRAK-OH Material Handling System IOM Manual Installation
3-8 © 2023 Nordson Corporation
c. Pull up the claw plunger, then pull out the handle (1) and safely remove the entire strip
claw from the station (2) (Figure 3-10 and Figure 3-11).
Figure 3-10 Removing Strip Claw 1
Figure 3-11 Removing Strip Claw 2
3. Push the strip transfer claw base assembly to the center of the plasma chamber area
(Figure 3-12).
Figure 3-12 Push Strip Transfer Claw to Center