1OM-1064-002.pdf - 第107页

1. Notes 0004-002 2-9 Tg0246-PM-OP How to Close the Supply Cover (1) Hold the handle firmly with both hands and push down to its lower limit slowly . Fig. 2.3 (2) Make sure that the supply cover is at its lower limit and…

100%1 / 244
1. Notes
Fig. 2.2
(3) Confirm that the supply cover is securely fixed.
CAUTION
Insufficient fixation causes the supply cover to
fall down.
1.5 Opening and Closing of Supply Cover
CAUTION
If there are more than one person, ensure
good communication by giving loud verbal
instructions for safety purposes.
Confirm that no obstacle, etc., exist around
the opening of the supply cover and then
open or close the supply cover.
Purpose of Opening or Closing
To supply components after component shortage.
To remove mispicked components.
To replace each feeder.
To perform the program change operation.
Others
How to Open or Close the Supply Cover
How to Open the Supply Cover
(1) Hold the handle firmly with both hands and push the lock button 1
to unlatch.
(2) Lift the supply cover to its upper limit. Then fix it securely.
0004-002 2-8 Tg0246-PM-OP
1. Notes
0004-002 2-9 Tg0246-PM-OP
How to Close the Supply Cover
(1) Hold the handle firmly with both hands and push down to its lower
limit slowly.
Fig. 2.3
(2) Make sure that the supply cover is at its lower limit and then release
the handle.
1. Notes
1.6 Opening and Closing of Maintenance Cover
CAUTION
Stop operation and set the power breaker to
“OFF” before opening or closing the main-
tenance cover.
To prevent the power breaker from being set
to “ON” by mistake, lock the power breaker
using a padlock kept by the person in charge.
Follow the instructions described in “5.1
Power Breaker Box of Section 1”.
If there are more than one person, ensure
good communication by giving loud verbal
instructions for safety purposes.
Confirm that no obstacle, etc., exist around
the opening of the maintenance cover and
then open or close the maintenance cover .
Purpose of Opening or Closing
To perform the program change operation.
Conveyor Width Adjustment
Setting of P.C.B. Support Pins
Changing of P.C.B. Transfer Mode (Direction Change of Stopper Block)
To perform maintenance and inspections work. (Cleaning, Lubrica-
tion, Inspection, etc.)
Others