1OM-1064-002.pdf - 第179页
3. AUTO OPN SUB-MENU Display *1 1 [RECALL MESSAGES] Key When this key is pressed, the “RECALL MESSAGES” display opens, enabling the selection of menu keys to recall device errors, handling er- rors, recognition errors, m…

3. AUTO OPN SUB-MENU Display
9910-001 3-9 Tg0246-PM-OP
*4 [TRAY L [NEUTRAL]/[LOCAL]/[LINE]] and [TRAY R (NEUTRAL]/
[LOCAL]/[LINE]] Keys (Options)
These keys are used to set the multi-layer tray feeder (L) or (R) in the
connection mode (line).
The label in [ ] shows the condition of the multi-layer tray feeder.
[NEUTRAL] : The multi-layer tray feeder is in the same condition as
that set when power is supplied.
[LOCAL] : The multi-layer tray feeder is in the “Local” mode. As
it is separated forcibly from the main machine, the au-
tomatic operation cannot be performed.
Manual operation is possible with the touch panel on
the multi-layer tray feeder side.
[LINE] : The multi-layer tray feeder is connected forcibly to the
main machine.
The multi-layer tray feeder is set ready for automatic
operation.
*5 UPPER MAGAZINE or LOWER MAGAZINE (Options)
These labels indicate whether or not the upper or the lower magazine on
the multi-layer tray feeder is set ready.
ON (Green) : Ready
OFF : Component Supply Possible
Function Keys
*6 [PROGRAM CHANGE] Key
This key is used to change current pattern program.
Refer to “3. Program Change of Section 4” for details.
*7 [SEMI-AUTOMATIC OPERATION] Key
This key is used to call the start-up menu for component placement start-
ing in the middle of pattern program data steps.
The related functions are used to reset the machine to the normal condi-
tion and start up the operation again after power is shut off during opera-
tion or to re-start the operation in the middle of steps after system clear
operation.
*8 [OPERATION MODE] Key
When this key is pressed, the “OPERATION MODE” display opens. Ba-
sically parameters for operation mode are set in the current pattern pro-
gram data. When some of the parameters (feeder alternate cancel, etc.)
must be modified according to situational changes and the required menu
key is pressed at the “OPERATION MODE” display, the corresponding
display opens, enabling the alteration of parameters set in the data boxes
labeled such as “RECOVERY MODE” (reserved function), etc.
*9 [RECOVERY OPN TEACHING OPN] Key
When this key is pressed, the “RECOVERY OPN TEACHING OPN” dis-
play opens, enabling the selection of menu keys to edit or correct pattern
program data, to change the feeding angle of a packaged component, to
edit or correct feeder (B) offset data, etc.
*10 [PRODUCT CHANGE] Key
This key is used to set up the conveyor width, etc.
Refer to “4. Product Change of Section 4” for details.

3. AUTO OPN SUB-MENU Display
*11 [RECALL MESSAGES] Key
When this key is pressed, the “RECALL MESSAGES” display opens,
enabling the selection of menu keys to recall device errors, handling er-
rors, recognition errors, machine information, etc., which occurred in the
past.
Each data is displayed in order of the error occurrence.
Refer to “4. Recall Messages of Section 3 in Volume 4” for details.
*12 [MANAGEMENT DATA] Key
When this key is pressed, the “MANAGEMENT DATA” display opens,
enabling the selection of menu keys to check management data such as
pattern program management data, time management data, component han-
dling error rate data, etc.
It is also possible to check situations such as nozzle bypass rate and nozzles
and feeders whose pick-up rates have deteriorated.
Refer to “3. Management Data of Section 3 in Volume 4” for details.
*13 [TRAY PICK-UP MATRIX] Key (Option)
The matrix data of the multi-layer tray feeder (option) can be referred to
or changed.
*14 [PICK-UP LOCATION] Key
When this key is pressed, the “PICK-UP LOCATION” display appears on
the screen, enabling to teach the component pick-up location through
manual alignment operation.
Refer to “6.9 PICK-UP LOCATION Display of Section 3 in Volume 4”
for details.
9910-001 3-10 Tg0246-PM-OP

3. AUTO OPN SUB-MENU Display
*15 [INDIVIDUAL FDR. ENABLE/DISABLE] key
This key is used to confirm the alternate feeder change or to instruct the compo
nent supply feeder operation completion. Refer to Section 3, Alternate Function
Valid/Invalid Setting for details.
Footnote
*16 Prohibited operation messages are displayed.
Table 3.1-
1
0103-003 3-11 Tg0246-PM-OP
Footnote
CANNOT SELECT MENU IN [PAUSE] MODE.
CANNOT MODIFY DATA IN [PAUSE] MODE.
CANNOT SAVE DATA IN [PAUSE] MODE.
CANNOT SELECT MENU IN [RUN] OR [WAIT] MODE.
CANNOT MODIFY DATA IN [RUN] OR [WAIT] MODE.
CANNOT SAVE DATA IN [RUN] OR [WAIT] MODE.
CANNOT SELECT MENU IN [RUN], [WAIT], OR [PAUSE] MODE.
CANNOT MODIFY DATA IN [RUN], [WAIT], OR [PAUSE] MODE.
CANNOT SAVE DATA IN [RUN], [WAIT], OR [PAUSE] MODE.
CANNOT SAVE CURRENT PROGRAM IN [RUN], [WAIT], OR [PAUSE] MODE.
CANNOT PERFORM OPERATION.
CANNOT SELECT MENU DURING MACHINE OPERATION.
CANNOT SELECT MENU DURING DATA COMMUNICATION WITH EXTERNAL DEVICE.
RECOGNITION DEVICE NOT READY.
SELECT CORRECT DATA.
CURRENT PATTERN PROGRAM NOT SPECIFIED.
BROKEN PATTERN PROGRAM DATA.
“PASSED” MODE SET IN OPERATION DATA.
CANNOT PERFORM OPERATION IN “PASSED” MODE.
OPERATION DENIED BY LOGIN TYPE.
PLEASE PRESS THE [RESET] BUTTON TOGETHER.
CANNOT SELECT MENU EXCEPT [PAUSE] MODE.
CANNOT SELECT MENU DURING TRAY OPERATION.
NO SAVING AREA IN FD.
CANNOT FIND THE FILE IN FD.
WRONG FLOPPY DISK.
CANNOT BE SAVED ON A WRITE-PROTECTED FD.
CANNOT READ THE DATA.
THE PATTERN PROGRAM DATA IS TOO LARGE FOR THE AVAILABLE MEMORY SPACE.
PLEASE INPUT CORRECT FDR#.
CANNOT MODIFY DATA DURING ATTACHED NOZZLE WITH HEAD.
CAN NOT OPERATION, BECAUSE DOES NOT FRONT PANEL.
CAN NOT OPERATION AT COMBINATION OF DESIGNATED HEAD AND FEEDER.
CAN NOT OPERATION, BECAUSE DOES NOT REAR PANEL.
ZERO BACKUP UP/DOWN AXIS (BPC-AXIS).
P.C.B. ON P-CONVEYOR WAS NOT DETECTED.
TROUBLE OCCURRED IN INTERNAL PROCESSING.
PLEASE INPUT CORRECT COMPONENT THICKNESS.
PLEASE INPUT NOZZLE TYPE.
CANNOT SELECT MENU DURING TEACHING RESULT DATA NOT EXIST.
CANNOT TEACH START MENU, ILLEGAL PLACEMENT POSITION.
CAN NOT OPERATION AT COMBINATION OF DESIGNATED CARRIER TYPE AND FEEDER.
PLEASE COLLECT COMPONENT.
CANNOT PERFORM OPERATION IN HEAD SKIP OR BEAM LOCK.
DISABLE OVER-WRITE MODE