7. Starting, Emergency Stop, and T emporary Stop (Pause) Operations for Automatic Operation (“P ASS” Mode) 7.5 Emergency Stop 7.5.1 Cause and Symptom of Emergency Stop Cause • The machine stops immediately when the [EMER…

7. Starting, Emergency Stop, and Temporary Stop (Pause) Operations for Automatic Operation (“PASS” Mode)
7.3 Stop Procedure
7.3.1 General Stop Procedure
• Press the [STOP] or the [PAUSE] button.
The operation stops.
7.3.2 Automatic Stop Procedure
• Stop the input machine.
The machine processes all P.C.B.’s on the system line, discharges them, and
stops running automatically.
Notes: (a) When “ENABLE” is set in the “AUTO STOP MODE” at the
“P.C.B. TRANSFER MODE SET-UP” display, the automatic op-
eration stops automatically. (Hierarchical Sequence: “DEVICE
DATA” → “P.C.B. TRANSFER MODE SET-UP” Display)
(b) When a machine of another brand is connected to the system line,
this function may not work.
7.3.3 Emergency Stop Procedure
• To stop the machine immediately in an emergency, press one of the [EMER-
GENCY STOP] buttons.
Power to the loads is shut off and the machine stops running instantaneously.
Refer to “7.5.2 Reset and Start Procedure from Emergency Stop of Section
2” for details on how to reset the machine from emergency stop.
7.4 Possible Operations during Automatic Operation
In the case of the automatic operation (PASS), the possible operations are the
same as the automatic operation (placement).
Refer to “6.5 Operational Displays during Automatic Operation of Section 2”
for details.
9910-001 2-66 Tg0246-PM-OP

7. Starting, Emergency Stop, and Temporary Stop (Pause) Operations for Automatic Operation (“PASS” Mode)
7.5 Emergency Stop
7.5.1 Cause and Symptom of Emergency Stop
Cause
• The machine stops immediately when the [EMERGENCY STOP] button is
pressed.
• The machine stops immediately when the supplied air pressure drops.
• The machine stops immediately when a circuit breaker (circuit breaker used
for P.C.B. positioning, the vacuum pump, the control DC power supply,
etc.) related to the system and placement is shut off.
• The machine stops immediately when the power for the communication line
(remote I/O) is not supplied.
Symptom
• The [POWER ON] button turns red, indicating that the power for the loads
is shut off.
(When the circuit breaker is shut off, the LED of the [POWER ON] button
(-HD50) may extinguish without turning red.)
9910-001 2-67 Tg0246-PM-OP

7. Starting, Emergency Stop, and Temporary Stop (Pause) Operations for Automatic Operation (“PASS” Mode)
7.5.2 Reset and Start Procedure from Emergency Stop
(1) Before pressing the [POWER ON] button to re-supply power to the ma-
chine, check and remove the cause of emergency stop and re-check each
section.
• Check the Condition of Each Individual Device.
• Set the P.C.B. under transfer at the correct position.
• Check the air pressure.
• Others
Refer to “Volume 3 : Troubleshooting” for details.
(2) Check that the maintenance cover, the supply cover, and the safety bar
are closed.
(3) Press the [POWER ON] button to re-supply power to the machine.
• Press and hold the [POWER ON] button for a few seconds.
• The LED of the [POWER ON] button (-HD50) illuminates in green,
indicating that power to the machine is supplied.
If the green LED does not illuminate (the LED stays in red), re-check
and remove the cause of the emergency stop.
• After the [POWER ON] button is pressed, the self-diagnostics func-
tion works on the recognition unit for a few minutes and no operation
becomes available.
Wait until the origin mark “” appears before “RECOGNITION” in
the “ORIGIN MONITOR” field at the “AUTO OPN. MODE <PLACE-
MENT>” display.
(4) After a “” mark has appeared before “RECOGNITION”, perform the
zeroing operation to zero each individual device.
0004-002 2-68 Tg0246-PM-OP