4.2 Lifted Nozzle Detection Sensors These sensors are used to protect the placement heads when a vacuum nozzle is jerked out of the nozzle stocker while the X/Y beam is moving. 9910-001 25 Tg0246-PM-OP 4.2 Lifted Nozzle …

[Beam Approach
Detection Sensor]
C(A)-BPH027
[Lifted Feeder Detection A1] Sensors
BPH053
[Lifted Nozzle Detection A1] Sensors
F(A1)-BPH061
[YA-Axis Stationary
Position Stopper
Backward Limit]
Sensor
BPH029
[Lifted Feeder Detection
A2] Sensors
BPH054
[Lifted Feeder Detection B2] Sensors
BPH056
[Lifted Feeder Detection
B1] Sensors
BPH055
[Lifted Nozzle Detection
B1] Sensors
F(B1)-BPH061
[YB-Axis Stationary Position Stopper
Backward Limit] Sensor
BPH031
4. Machine Protection Sensors
4.1 Lifted Feeder Detection Sensors
These sensors are used to prevent any machine operation (to protect the ma-
chine) when a tape feeder is not installed correctly.
4. Machine Protection Sensors
9910-001 24 Tg0246-PM-OP
(Rear Side) (Side A Beam)
(Front Side) (Side B Beam)
Sensor Name Symbol Countermeasures
[Lifted Feeder Detection
A1] Sensors (Rear Side)
[Lifted Feeder Detection
A2] Sensors (Rear Side)
[Lifted Feeder Detection
B1] Sensors (Front Side)
[Lifted Feeder Detection
B2] Sensors (Front Side)
BPH053
BPH054
BPH055
BPH056
When one of these sensors is turned off (E/NR: Light Emitted
and Not Received), the following measures are taken.
•
The power to drive both X/Y beams (Sides A beam and B
beam) is shut off.

4.2 Lifted Nozzle Detection Sensors
These sensors are used to protect the placement heads when a vacuum nozzle
is jerked out of the nozzle stocker while the X/Y beam is moving.
9910-001 25 Tg0246-PM-OP
4.2 Lifted Nozzle Detection Sensors
4.3 Beam Approach Detection Sensor
This sensor is used to detect that both X/Y beams are abnormally approaching
and protect the X/Y beam.
4.4 Stationary Position Stopper Detection Sensors
These sensors are used to check whether the stationary position stopper of the
X/Y beam has moved back during X/Y beam movement and the X/Y beam is
set ready to be moved.
Sensor Name Symbol Countermeasures
[Lifted Nozzle Detection A1]
Sensor (Rear Side)
[Lifted Nozzle Detection B1]
Sensor (Front Side)
F(A1)-BPH061
F(B1)-BPH061
When one of these sensors is turned off (E/NR:
Light Emitted and Not Received) while the X/Y
beam is moving, the following measures are
taken.
•
The power to drive both X/Y beams (Sides A
beam and B beam) is shut off.
Sensor Name Symbol Countermeasures
[Beam Approach Detection] Sensor C(A)-BPH027 When this sensor is turned off (E/NR: Light
Emitted and Not Received) while the X/Y beam is
moving, the following measures are taken.
•
The power to drive both X/Y beams (Sides A
beam and B beam) is shut off.
Sensor Name Symbol Countermeasures
[YA-Axis Stationary Position
Stopper Backward Limit] Sensor
(Rear Side)
[YB-Axis Stationary Position
Stopper Backward Limit] Sensor
(Front Side)
BPH029
BPH031
When one of these sensors is turned off (E/R:
Light Emitted and Received) while the X/Y beam
is moving, the following measures are taken.
•
The power to drive both X/Y beams (Sides A
beam and B beam) is shut off.

[LX1-Axis Excessively Inserted
Nozzle Detection] Sensor
MB(X)-BPX121
[LX1-Axis Level
Detection (4)] Sensor
MB(X) BPH127
[LX2-Axis Excessively Inserted
Nozzle Detection] Sensor
MC(X)-BPX121
[LX1-Axis Level
Detection (3)] Sensor
MB(X) BPH126
[LX1-Axis Level
Detection (2)] Sensor
MB(X) BPH125
[LX1-Axis Level
Detection (1)] Sensor
MB(X) BPH124
[LX2-Axis Level
Detection (4)] Sensor
MC(X) BPH127
[LX2-Axis Level
Detection (3)] Sensor
MC(X) BPH126
[LX2-Axis Level
Detection (2)] Sensor
MC(X) BPH125
[LX2-Axis Level
Detection (1)] Sensor
MC(X) BPH124
Sensor Name Symbol Countermeasures
[LA1-Axis Excessively
Inserted Nozzle Detection]
Sensor (Rear Left Head)
[LA2-Axis Excessively
Inserted Nozzle Detection ]
Sensor (Rear Right Head)
[LB1-Axis Excessively
Inserted Nozzle Detection]
Sensor (Front Right Head)
[LB2-Axis Excessively
Inserted Nozzle Detection]
Sensor (Front Left Head)
MB(A)-BPX121
MC(A)-BPX121
MB(B)-BPX121
MC(B)-BPX121
When one of these sensors is turned off (E/NR: Light
Emitted and Not Received), the following measures are
taken.
•
The power to drive the pertinent up/down axis is shut
off.
4.5 Excessively Inserted Nozzle Detection Sensors
These sensors are used to protect the placement heads when a vacuum nozzle
is inserted excessively due to a mistake in the pattern program.
• “X” in ( ) represents “A” or “B” in the figure below.
4.5 Excessively Inserted Nozzle Detection Sensors
(Head 1) (Head 2)
0103-002 26 Tg0246-PM-OP