1OM-1064-002.pdf - 第223页
4. Product Change *3 ST A TUS “RUN” : The machine is performing the set-up operation. “READY” : The set-up operation is completed. “NOT READY” : The set-up operation is completed but the current posi- tion is not located…

4. Product Change
4.1 Selection of Set-Up Menus and Overall Set-Up Op-
eration
When the [PRODUCT CHANGE] key is pressed at the “MANUAL MODE”
display, the following display appears on the screen.
When the [PRODUCT CHANGE] key is pressed at the “AUTO OPN.
SUB-MENU” display, the same display appears on the screen.
*4
*3
*1
*2
9910-001 4-6 Tg0246-PM-OP
4. Product Change
Fig. 4.3
• When this display is active and the [MOVE] button is pressed, the machine
automatically sets up all the devices for which “ON” is set in the “MODE”
data boxes at the “SET-UP DATA” display. (Hierarchical Sequence: “DATA
EDIT” Display → “PATTERN PROGRAM” Display → “SET-UP DATA”
Display)
Note: When the [OPERATION/SET UP] switch is set to the “SET UP”
side, the set-up operation cannot be performed.
Ref.: Before the conveyor width set-up operation is initiated, each con-
veyor is automatically activated to check that no P.C.B. is located at
any irregular position.
*1 [CONVEYOR WIDTH] Key
When this key is pressed, the “CONVEYOR WIDTH” display appears on
the screen, enabling the manual set-up operation of each individual de-
vices.
*2 FUNCTION (“ON” or “OFF”)
Shown in the text box is the parameter set at the “SET-UP DATA” display.
(Hierarchical Sequence: “PATTERN PROGRAM” Display → “SET-UP
DATA” Display)

4. Product Change
*3 STATUS
“RUN” : The machine is performing the set-up operation.
“READY” : The set-up operation is completed.
“NOT READY” : The set-up operation is completed but the current posi-
tion is not located (managed).
“---” : The current position or program is indefinite.
“---” (Red) : “OFF” is set as set-up data.
*4 CLEARANCE
“CLEARANCE” is the data which gives some leeway (slightly wider than
P.C.B. size Y) to the conveyor width in the pattern program data.
• Data Input Range
-5.0 to +5.0 mm (Recommended Value: 0.5 mm)
The actual conveyor width becomes “P.C.B. Size Y + Clearance”.
Input Method of Clearance Data
• After selecting the key of the data to be set, press the [ ] key to increase
the value or the [ ] key to decrease in the increments of 0.1 mm.
• When the value is out of the input range, the buzzer in the touch screen
sounds but no change is made in the parameter.
Note: No data can be changed while a device is being activated.
9910-001 4-7 Tg0246-PM-OP

4.2 Manual Set-Up at Each Display (Display for Each
Device)
When the [CONVEYOR WIDTH] key is pressed at the “PRODUCT
CHANGE” display, the following display appears on the screen.
*2
*6
*5
*4
*1
*3
9910-001 4-8 Tg0246-PM-OP
4. Product Change
Fig. 4.4
*1 P.C.B. SIZE Y
Shown is the parameter set in the current pattern program data.
“--------” appears when the current program is indefinite.
*2 LOCATION
The currently managed width appears in this text box.
“--------” appears when the current location is indefinite or is not managed.
*3 STATUS
“RUN” : The machine is performing the set-up operation.
“READY” : The set-up operation is completed.
“NOT READY” : The set-up operation is completed but the current posi-
tion is not located (managed).
“---” : The current position or program is indefinite.
“---” (Red) : “OFF” is set as set-up data.
*4 DESIGNATED WIDTH
The same parameter as that in the “P.C.B. SIZE Y” text box appears in this
data box.
When the current program is indefinite, “0.0 mm” appears instead.
*5 CONVEYOR WIDTH CLEARANCE
Shown is the backup value of the clearance data.
*6 [ZERO DEVICE [MOVE]] Key
When the [ZERO DEVICE [MOVE]] key is selected and the [MOVE] but-
ton is pressed, the conveyor width is zeroed.
It is displayed whether or not the conveyor width is zeroed in the “STA-
TUS” text box.
: This indicates that the conveyor width is zeroed completely.