1OM-1064-002.pdf - 第42页

9910-001 1-12 Tg0246-PM-OP 2. Specifications Supply Pressure 0. 49 to 0.69 MPa (5 to 7 kg f/cm 2 ) Dry and Clean Air (Moisture, oil, and dust are remov ed.) Set Pressure 0.49 MPa (5 kg f/cm 2 ) 31. Air Supply • Dray and …

100%1 / 244
2. Specifications
9910-001 1-11 Tg0246-PM-OP
Fiducial Marks
Through
Hole
s
Shapes
Pad Marks
Size 0.5 to 2.0 mm
Material
Copper Leaf (Au and Ni plating possible but mirror surfaces
cannot be used.)
Solder-Plated Marks (Consult our sales personnel for details.)
Solder Leveler (Consult our sales personnel for details.)
27. Fiducial Marks
Notes : (a) A through hole or a pad mark should have only one land which
is directed in increments of 45°. Consult our sales personnel for
details.
(b) The fiducial mark should make ample contrast with the
surroundings.
(c) A test may be required when the fiducial mark cannot be
recognized because of the extreme warpage of the PCB.
(d) Anything like a pattern similar to a fiducial mark should not
exist in the designated window. If exists, it may cause a false
recognition. Also the shape (a cutout, a punched hole) of the
PCB, the light reflected from a structure, or the light from the
external elements may sometimes interfere with the recognition.
Consult our sales personnel for details.
(e) Consult our sales personnel for details if you require additional
information.
28. Specifications of
Automatic Setup
Function
When a program change is made, the PCB transfer conveyor width and the
PCB backup pin’s up/down movement are automatically set up.
Minimum Unit of Movement
PCB Transfer Conveyor Width : 0.1 mm
(Resolution : 0.0025 mm/pulse)
PCB Backup Pin Up/Down Movement : 0.01 mm
(Resolution : 0.00048075 mm/pulse)
29. Power Supply 200 ± 20 V AC, 3-Phase, 50/60Hz
Connected to the power supply unit (3-phase 4-wire system)
(One of the four wires is used as a ground wire.)
30. Maximum Power
Consumption
Approx. 7 kVA
Others
Others
(Under Development)
9910-001 1-12 Tg0246-PM-OP
2. Specifications
Supply
Pressure
0. 49 to 0.69 MPa (5 to 7 kgf/cm
2
)
Dry and Clean Air (Moisture, oil, and dust are removed.)
Set
Pressure
0.49 MPa (5 kgf/cm
2
)
31. Air Supply
Dray and Clean Air
Moisture : Dew Point 17 or lower (Atmospheric Pressure)
Oil : 0.1 mg/m
3
or less (ANR)
Dust : Solid Material 0.01 µm or less
32. Air Consumption Approx. 20 l/min (ANR)
33. Vacuum Pressure 93 kPa (70 cmHg)
34. Environmental
Condition
Temperature : 20 ± 10°C
Humidity : 30 to 80% (Avoid dew condensation.)
35. Basic Dimensions 1,700 (width) × 2,228 (depth, excluding the safety bar) × 1,565 mm (height)
Notes : (a) The height becomes 2,100 mm when the light tower is included.
(b) The depth becomes 3,118 mm when the safety bar is included.
2,420 kg (only the main body section)
Note : The mass changes depending on the type of feeders to be installed.
Mass of Options (For Reference)
Name Mass (kg)
Tape Feeder The mass depends on
feeder types.
Stick Feeder (Vibratory) Approx. 6.5/feeder
Multi-Layer Tray Feeder Approx. 180/feeder
Note : The mass related to components is not included.
36. Basic Mass
[Measuring Condition]
Measuring Position
Position 1 m away and 1.6 m in height from the machine.
Noise Measuring Instrument
Model: RION NA-60 (Range A)
Requirements for Operation
Test Run Actions: No P.C.B. Transfer, No Component Picks/No
Recognition/No Placement, Repetition of Stages 11 and 12 for Multi-Layer
Tray Feeders L/R, Only One 32 mm Tape Feeder Activated (FDR No. 228)
Measuring
Point
*1 *2 *3 *4 *5 *6 *7 *8
Remarks
Measured
Noise
Value
[
dB
]
70.8 70.6 70.8 68.4 68.7 69.6 68.4 69.1
Background
Noise
(Surroundings)
48.7 [dB]
37. Measured Noise
Value
2. Specifications
9910-001 1-13 Tg0246-PM-OP