4. SEMI-AUTOMA TIC OPERA TION *2 [U-NO], [P-NO] and [O-NO] key Step No. from which the placement operation starts When repetitive placement data is not used (No O-No. data), “----” ap- pears in the “O-NO” data box. T o s…

100%1 / 244
4. SEMI-AUTOMATIC OPERATION
*4*9*12*11*8
*6
*7
*3
*2
*5
*1
*10
4. SEMI-AUTOMATIC OPERATION
This function enables special start-up operations such as resetting and con-
tinuous starting of semi-automatic operation from the P.C.B. in the middle
of process after power is turned off and starting of placement operation
from the middle of steps after system clear.
Components can be placed on the positioned P.C.B. from the desired step
No. or only one component in the desired step No. can be placed on the
P.C.B.
4.1 Normal Step Designation (Without Non-Placement
Steps)
When the [SEMI-AUTOMATIC OPERATION] key is pressed at the “AUTO
OPN SUB-MENU” display, the following display appears on the screen.
Note: This key can be selected only when the machine is in the “STOP” mode.
Fig. 3.3
*1 [BEAM-A STEP] and [BEAM-B STEP] keys
Specify the beam to be operated.
When the selected key illuminates in blue, the corresponding beam can be
operated.
If not, the beam cannot be operated.
Every time the key is pressed, the key turns blue or not.
0004-002 3-13 Tg0246-PM-OP
4. SEMI-AUTOMATIC OPERATION
*2 [U-NO], [P-NO] and [O-NO] key
Step No. from which the placement operation starts
When repetitive placement data is not used (No O-No. data), “----” ap-
pears in the “O-NO” data box.
To set step No., select this key and enter a parameter using the ten-key
pad. Then, press the [SET] key.
(When the step No. in the “U-NO” data box is changed, “0001” is auto-
matically set in the “P-NO” and “O-NO” data boxes.)
Note: When a non-existing step No. is specified and the [SET] key is
pressed, an error message is issued, indicating that no data entry is
possible.
*3 Ten-Key Pad for Parameter Entry
*4 Entered Parameter Display Section
When the [SET] key is pressed, the displayed parameter is specified as
operation start step *2.
*5 [ ] and [ ] key
These keys are used to change the step No. from which the placement
operation starts.
To change the step No., select the step No. data box *2 and press the [ ]
or the [ ] key. The step No. scrolls up or down one by one.
When the [ ] key is pressed, the step No. increases. Pressing the [ ] key
decreases the step No.
*6 Component IDs used in the specified steps
Component IDs used in the steps as operation start ones are displayed.
*7 Comments of the step Nos. specified as operation start steps are displayed.
*8 DEVICE ORIGIN
Origin Monitor Section
When the devices are located at their origins, this label turns green.
When they are not at their origins, it turns light red.
Note: Semi-automatic operation cannot be performed when the devices
are not at their origins.
*9 [P.C.B. LOCATION] key
This display section indicates how the P.C.B. is positioned.
When a P.C.B. is correctly positioned, this key turns green.
When there is no P.C.B. or a P.C.B. is not positioned correctly, it turns
light red.
Note: When a P.C.B. is not positioned correctly, the semi-automatic op-
eration cannot be performed.
When the [P.C.B. LOCATION] key is pressed, the “MANUAL TRANS-
FER OPERATION” display appears on the screen.
Refer to “8. Manual Transfer Operation of Section 4” for details.
When *8 and *9 are green, it indicates that the semi-automatic operation
is set ready.
9910-001 3-14 Tg0246-PM-OP
4. SEMI-AUTOMATIC OPERATION
*10 [FULL AUTO CONT [START]] Key
This key is used to specify the continuous operation from the operation
start step No.
When the [START] button is pressed after this key is selected, the “AUTO
OPN MODE (PLACEMENT)” display appears on the screen and auto-
matic operation starts.
Note: FULL AUTO CONT: Normal automatic operation is performed
continuously from the steps specified in the “U-NO”, “P-NO” and
“O-NO” data boxes.
*11 [FULL AUTO STEP [MOVE]] Key
This key is used to specify step operation from the operation start No.
When the key is selected and the [MOVE] button is pressed, the “AUTO
OPN MODE (PLACEMENT)” display appears on the screen and auto-
matic operation starts.
When the machine is set in the “PAUSE” mode, the automatic operation
stops once because this is a step operation.
Note: FULL AUTO STEP: Every time the [MOVE] button is pressed,
step operation is performed from the steps specified in the “U-
NO”, “P-NO”, and “O-NO” data boxes.
*12 [1 CMPNT PLACE [MOVE]] Key
This key is used to specify placement of one component in the operation
start step No.
When this key is selected and the [MOVE] button is pressed, the machine
places only one component in the operation start step No. After that, all
devices return to their origins and stop.
Note: 1 CMPNT PLACE: The machine places only one component in
the steps specified in the “U-NO”, “P-NO”, and “O-NO” data
boxes.
9910-001 3-15 Tg0246-PM-OP