1OM-1064-002.pdf - 第199页
5. Operation Mode “ENABLE/DISABLE” “ENABLE EXIST” Set this when there still exist some components in the feeder installed on the destination feeder slot (FDR. NO.) for alternate use. Note: Although “DISABLE EMPTY” can al…

5. Operation Mode
Feeder No. Keys
These keys are labeled with feeder Nos.
The keys are also color-coded, indicating how the alternate
feeder function is working.
Pink : DISABLE EMPTY
Light Green : ENABLE EXIST
Dark Gray : NOT USED
Pressing each key opens the “ALTERNATE FEEDER LINK
LIST” display (Fig. 3.14).
[FDR. BASE #1], [FDR. BASE #2], [FDR. BASE #3], and
[FDR. BASE #4] Keys
When one of these keys is selected, the feeder No. keys allo-
cated to the selected feeder base appear in the display, en-
abling the operator to designate the desired feeder Nos. to
check how the alternate function is working on the selected
feeders.
“CMPNT ID:”
Displayed is the component ID which is allocated to the se-
lected feeder No.
“FDR NO”
Displayed are the selected feeder Nos.
• This shows the feeder No. of the component data.
• This shows the actual feeder No.
This indicates the feeder Nos. where component No. off-
set (reserved data) specified in the operation data is added.
In the left figure (an example), “+0” is set as component
No. offset.
Note: “---” appears in the “FDR NO” data field, indi-
cating the no feeder can be installed for the slot
No.
“DIR”
Displayed are the directions specified in the component li-
brary data. Components are supplied in the specified direc-
tions.
“TYPE”
Displayed are the types of components specified in the com-
ponent library data.
“MODE”
Displayed are the modes (ON or OFF) specified for “AL-
TERNATE FDR.” in the component data.
“ALT FDR NO”
Displayed is the destination feeder No. for alternate use of
the selected feeder No.
9910-001 3-29 Tg0246-PM-OP

5. Operation Mode
“ENABLE/DISABLE”
“ENABLE EXIST”
Set this when there still exist some components in the feeder installed
on the destination feeder slot (FDR. NO.) for alternate use.
Note: Although “DISABLE EMPTY” can also be set, be sure to set
“ENABLE EXIST” when the feeder is replenished with com-
ponents.
“DISABLE EMPTY”
This is automatically set for the feeder Nos. when a component short-
age error is detected.
Notes: (a) “DISABLE EMPTY” can be set only when two or more
feeders are linked.
(b) In the case of an unlinked feeder slot No. (feeder slot No.
for which the alternate feeder mode is not specified), the
“ALTERNATE FEEDER LINK LIST” display can be
opened but “ENABLE EXIST” or “DISABLE EMPTY”
cannot be specified for the feeder slot No.
(c) The parameters “ENABLE EXIST” and “DISABLE
EMPTY” are retained (saved in memory) after “POWER
OFF” or “System Clear” operation is performed.
(d) When the program change operation is performed and
the component data is used for the different program,
“ENABLE EXIST” is set for all feeders.
When the program change operation is performed and
the component data is used for the same program, no
change is made in the “ENABLE/DISABLE” settings.
[ALL FDR. EXIST] Key
When this key is selected and the [SET] key is pressed, “ENABLE
EXIST” is set for all linked feeders where components of the same type
are provided.
Operation Procedure (Using the Alternate Feeder Function)
(1) Confirm that “ENABLE” is set in the “ALTERNATE FEEDER
MODE” text box.
When “DISABLE” is specified in the text box, set “ON” in the
“MODE” data field of the label “ALTERNATE FEEDER” at the
“COMPONENT DATA EDIT” display. (Hierarchical Sequence:
“DATA EDIT” Display → “PATTERN PROGRAM” Display →
“PATTERN PROGRAM EDIT” Display → “COMPONENT DATA”
Display → “COMPONENT DATA EDIT” Display)
(2) Set “ENABLE” in the “INDV. FDR. ENABLE/DISABLE” data box.
(3) Set “SUPPLY PRI” or “EP DATA” in the “ALTERNATE OPERA-
TION” data box.
(4) Press the [INDV. FDR. ENABLE/DISABLE] key. The “INDIVIDUAL
FDR ENABLE/DISABLE” display appears on the screen.
(5) Select the feeder No. keys for which the alternate feeder mode should
be set. The “ALTERNATE FEEDER LINK LIST” display appears
on the screen.
(6) Move the line cursor to the feeder No. for which the alternate mode
should be designated and set “ENABLE EXIST” for the feeder No.
Ref.: When the [ALL FDR. EXIST] key is selected and the [SET]
key is pressed, “ENABLE EXIST” is set for all linked feed-
ers where components of the same type are provided.
0004-002 3-30 Tg0246-PM-OP

5. Operation Mode
5.6 COMPONENT MISSING CHECK MODE Display
• This display allows the operator to determine whether or not the component
missing check mode should be enabled or disabled.
When the [COMP. MISSING CHECK MODE] key is pressed at the “OPERA-
TION MODE” display, the following display appears on the screen.
0004-002 3-31 Tg0246-PM-OP
Fig. 3.15
[DISABLE] Key
When this key is selected, “DISABLE” is set in the “COMP.
MISSING CHECK MODE” data box, indicating that the com-
ponent missing check mode is disabled.
[ENABLE] Key
When this key is selected, “ENABLE” is set in the “COMP.
MISSING CHECK MODE” data box, indicating that the com-
ponent missing check mode is enabled.