1OM-1064-002.pdf - 第156页

6. Starting, Emergency Stop, and T emporary Stop (Pause) Operations for Automatic Operation (“PLACE” Mode) Special Selection 9910-001 2-58 Tg0246-PM-OP RUN/W AIT PAUSE Possible Operations • Sav e O pe ration o f Manage m…

100%1 / 244
6. Starting, Emergency Stop, and Temporary Stop (Pause) Operations for Automatic Operation (“PLACE” Mode)
9910-001 2-57 Tg0246-PM-OP
RUN/WAIT PAUSE
Possible
Operations
Editing and Save Operation of Component
Library Data (Not for Current Pattern
Program)
Editing and Save Operation of Component
Library Data (Not for Current Pattern
Program)
Editing and Save Operations of Test Mode
Data other than P.E.C. and Component
Recognition Data
Editing and Save Operation of Offset Data
• Feeder (A) Offset
• Feeder (B) Offset
Impossible Operations
Shift to the "PROGRAM CHANGE" Display
Save Operation of Component Library Data
(Used in Current Pattern Program)
Save Operation of Auto Operation Set-Up Data
Save Operation of Device Data
• P.C.B. Transfer Mode Set-Up
Machine Communication Mode Set-Up
Tray Matrix Mode (Option)
Save Operation of Test Mode
Save Operation of Offset Data
Save Operation of Nozzle Stocker Data
Save Operation of Nozzle Library Information
Shift to the “PROGRAM CHANGE”
Display
Save Operation of Component Library
Data (Used in Current Pattern Program)
Save Operation of Auto Operation Set-Up
Data
Save Operation of Device Data
• P.C.B. Transfer Mode Set-Up
Machine Communication Mode Set-Up
Tray Matrix Mode (Option)
Save Operation of Offset Data
• Offset Data other than Feeder (A) Offset
and Feeder (B) Offset
Save Operation of Nozzle Stocker Data
Save Operation of Nozzle Library
Information
RUN/WAIT PAUSE
Possible
Operations
Editing and Save Operation of Current Pattern
Program Data with Another Name
Editing and Save Operation of Other Data (Not
Current One)
Editing and Save Operation of Current
Pattern Program Data with Another Name
Editing and Save Operation of Other Data
(Not Current One)
Impossible
Operations
Save Operation of Current Pattern Program
Data with Same Name
Save Operation of Current Pattern Program
Data with Same Name
Data Editing
Editing of Pattern Program
Data Editing
Others
6. Starting, Emergency Stop, and Temporary Stop (Pause) Operations for Automatic Operation (“PLACE” Mode)
Special Selection
9910-001 2-58 Tg0246-PM-OP
RUN/WAIT PAUSE
Possible
Operations
Save Operation of Management Data
Save Operation of Recalled Data (Recalled
Messages)
• RECALL DEVICE ERROR
• RECALL HANDLING ERROR
• RECALL MACHINE INFO
• RECALL COMP. RECOG. ERROR
Display of Device Check Data
Machine Program Information
Save Operation of Management Data
Save Operation of Recalled Data (Recalled
Messages)
Display of Device Check Data
Machine Program Information
Zeroing Operation
Manual Subsystem Operation
Manual Axis Operation
Impossible Operations
Save Operation of Recalled Data (Recalled
Messages)
Recalled Recognition Error Image
Editing and Save Operation of Manual Bypass
Data
Display of Device Check Data
• Input Check
• Memory Check
• Output Check
Shift to the “ZEROING OPERATION” Display
Shift to the “MANUAL SUBSYSTEM
OPERATION” Display
Shift to the “MANUAL AXIS OPERATION”
Display
Shift to the “UNIT ADJUSTMENT” Display
Shift to the “OFFSET TEACH” Display
Shift to the “DEVICE TEST” Display
Shift to the “HDD/FDD OPERATION”
Display
Editing and Save Operation of Manual
Bypass Data
Display of Device Check Data
• Input Check
• Memory Check
• Output Check
Shift to the “UNIT ADJUSTMENT”
Display
Shift to the “OFFSET TEACH” Display
Shift to the “DEVICE TEST” Display
Shift to the “HDD/FDD OPERATION”
Display
6. Starting, Emergency Stop, and Temporary Stop (Pause) Operations for Automatic Operation (“PLACE” Mode)
Machine Set-Up
RUN/WAIT PAUSE
Possible
Operations
Setting of Password
Setting of Light Tower and Alarm Data
Setting of Date and Time Data
Setting of Error Display Color
Setting of Screen Mode
Customization
Impossible
Operations
Setting of Password
Setting of Light Tower and Alarm Data
Setting of Date and Time Data
Setting of Error Display Color
Setting of Screen Mode
Customization
9910-001 2-59 Tg0246-PM-OP
Note: Some other operations may be possible or not, depending on whether
or not the operational requirements are fulfilled. Consult our sales per-
sonnel for details.