1OM-1064-002.pdf - 第154页

6. Starting, Emergency Stop, and T emporary Stop (Pause) Operations for Automatic Operation (“PLACE” Mode) 6.5 Operational Displays during Automatic Operation Automatic Operation Sub-Menu RUN/W AIT PAUSE Possible Operati…

100%1 / 244
6. Starting, Emergency Stop, and Temporary Stop (Pause) Operations for Automatic Operation (“PLACE” Mode)
To supply components whenever necessary
In the following cases, components can be supplied through the procedure
below.
Follow the procedure below to supply components before re-starting the
operation when the machine has stopped due to a stage or a tray in short of
components.
Follow the procedure below to supply components after a set-up operation
is performed.
(1) Press the [STOP] button to stop the machine.
(2) Open the “ELEVATOR UNIT” display. (Hierarchical Sequence: “LO-
CAL MODE” Display “MANUAL MODE” Display “ELEVATOR
UNIT” Display)
Select the [UPPER MAGAZINE CONNECT/DISCON] or the [LOWER
MAGAZINE CONNECT/DISCON] key and press the [MOVE] button
to separate the pertinent magazine from the elevator shaft.
(3) Open the “COMPONENT REPLENISHMENT” display (Fig. 2.35).
(4) Check the stage (pallet) and the block which caused a component short-
age error.
When a block is specified, press the No. key of the stage where a compo-
nent shortage error has occurred. The display (Fig. 2.36) appears on the
screen, enabling you to check the block data.
(5) Press the [X READY (LWR)] or the [X READY (UPR)] key of the feeder
unit where components should be supplied. “X” represents either “L” or
“R”.
The upper or the lower door is unlocked.
(6) Open the upper or the lower door and then the magazine door.
(7) Pull out the pallet on the stage where components should be supplied and
load it with components.
(8) Press the No. key of the stage in red (ON or flickering) at the display (Fig.
2.35) and the No. key of the block in red (ON or flickering) at the display
(Fig. 2.36). The keys turn violet.
(9) Confirm that all components are supplied completely and close all doors
(magazine, upper and lower doors).
(10) Press the [SUPPLY] key at the display (Fig. 2.35).
The display (Fig. 2.37) appears on the screen.
(11) Confirm that components are supplied completely and press the [YES]
key to declare the completion of component replenishment.
Pressing the [NO] key resumes the display (Fig. 2.35).
(12) Press the [L READY (LWR)] or the [L READY (UPR)] key when the
multi-layer tray feeder on the left side is ready. When the feeder on the
right side is ready, press the [R READY (LWR)] or the [R READY (UPR)]
key.
The door on the related side is locked, making it possible to operate the
machine with the feeder being connected.
Ref.: (a) When several pallets are short of components, follow Step (8) ev-
ery time components are supplied or another step (collective op-
eration) after all components are supplied.
(b) It is also possible to replenish the tray in the middle of processing
with components or replace it with another one. In this case, it is
required to update the tray matrix.
Refer to “7. Tray Pick-Up Matrix of Section 3”or “6.4 Matrix
Change Operations of Section 2” in the instruction manual of the
multi-layer tray feeders for details.
0004-002 2-55 Tg0246-PM-OP
6. Starting, Emergency Stop, and Temporary Stop (Pause) Operations for Automatic Operation (“PLACE” Mode)
6.5 Operational Displays during Automatic Operation
Automatic Operation Sub-Menu
RUN/WAIT PAUSE
Possible
Operations
Editing and Save Operation of Recalled
Data (Recalled Messages)
• RECALL DEVICE ERROR
• RECALL HANDLING ERROR
• RECALL MACHINE INFO
• RECALL COMP. RECOG. ERROR
Editing and Save Operation of Management
Data
Operation Mode
Recovery Operation
Teaching Operation
Change of Carrier Data
Feeder (B) Offset
Editing and Save Operation of Recalled
Data (Recalled Messages)
Editing and Save Operation of Management
Data
Editing and Save Operation of Tray Pick-
Up Matrix Data (Option)
Impossible
Operations
Semi-Automatic Operation (Full Auto Step)
Save Operation of Operation Mode
Save Operation of Recovery/Teaching
Operation Data
Editing and Save Operation of Recalled Data
(Recalled Messages)
Recalled Recognition Error Image
Editing and Save Operation of Tray Pick-Up
Matrix Data (Option)
Shift to the “PRODUCT CHANGE” Display
Shift to the “PROGRAM CHANGE” Display
Shift to the “PICK-UP LOCATION” Display
Semi-Automatic Operation (Full Auto Step)
Save Operation of Recovery/Teaching
Operation Data
Correction of Current Program
Correction of Component Library Data
Shift to the “PRODUCT CHANGE”
Display
Shift to the “PROGRAM CHANGE”
Display
Shift to the “PICK-UP LOCATION
Display
RUN/WAIT PAUSE
Possible
Operations
Zeroing Operation
Manual Subsystem Operation
Manual Axis Operation
Manual Transfer Operation
Impossible
Operations
Shift to the “PROGRAM CHANGE” Display
Shift to the “PRODUCT CHANGE” Display
Shift to the “ZEROING OPERATION” Display
Shift to the “MANUAL SUBSYSTEM
OPERATION” Display
Shift to the “MANUAL AXIS OPERATION”
Display
Shift to the “MANUAL NOZZLE CHANGE
OPERATION” Display
Shift to the “MANUAL TRANSFER
OPERATION” Display
Shift to the “PCB SUPPORT PINS SET-UP
MODE” Display
Shift to the “PROGRAM CHANGE”
Display
Shift to the “PRODUCT CHANGE”
Display
Manual Nozzle Change Operation
Shift to the “PCB SUPPORT PINS SET-
UP MODE” Display
Manual Mode
9910-001 2-56 Tg0246-PM-OP
6. Starting, Emergency Stop, and Temporary Stop (Pause) Operations for Automatic Operation (“PLACE” Mode)
9910-001 2-57 Tg0246-PM-OP
RUN/WAIT PAUSE
Possible
Operations
Editing and Save Operation of Component
Library Data (Not for Current Pattern
Program)
Editing and Save Operation of Component
Library Data (Not for Current Pattern
Program)
Editing and Save Operations of Test Mode
Data other than P.E.C. and Component
Recognition Data
Editing and Save Operation of Offset Data
• Feeder (A) Offset
• Feeder (B) Offset
Impossible Operations
Shift to the "PROGRAM CHANGE" Display
Save Operation of Component Library Data
(Used in Current Pattern Program)
Save Operation of Auto Operation Set-Up Data
Save Operation of Device Data
• P.C.B. Transfer Mode Set-Up
Machine Communication Mode Set-Up
Tray Matrix Mode (Option)
Save Operation of Test Mode
Save Operation of Offset Data
Save Operation of Nozzle Stocker Data
Save Operation of Nozzle Library Information
Shift to the “PROGRAM CHANGE”
Display
Save Operation of Component Library
Data (Used in Current Pattern Program)
Save Operation of Auto Operation Set-Up
Data
Save Operation of Device Data
• P.C.B. Transfer Mode Set-Up
Machine Communication Mode Set-Up
Tray Matrix Mode (Option)
Save Operation of Offset Data
• Offset Data other than Feeder (A) Offset
and Feeder (B) Offset
Save Operation of Nozzle Stocker Data
Save Operation of Nozzle Library
Information
RUN/WAIT PAUSE
Possible
Operations
Editing and Save Operation of Current Pattern
Program Data with Another Name
Editing and Save Operation of Other Data (Not
Current One)
Editing and Save Operation of Current
Pattern Program Data with Another Name
Editing and Save Operation of Other Data
(Not Current One)
Impossible
Operations
Save Operation of Current Pattern Program
Data with Same Name
Save Operation of Current Pattern Program
Data with Same Name
Data Editing
Editing of Pattern Program
Data Editing
Others