8. Shut-Down Operation (End of Production) Press the [POWER OFF] button on the operation panel. T urn off the power breaker ( { ) located on the front side of the machine to shut off the power completely . 8. Shut-Down O…

100%1 / 244
7. Starting, Emergency Stop, and Temporary Stop (Pause) Operations for Automatic Operation (“PASS” Mode)
7.5.2 Reset and Start Procedure from Emergency Stop
(1) Before pressing the [POWER ON] button to re-supply power to the ma-
chine, check and remove the cause of emergency stop and re-check each
section.
Check the Condition of Each Individual Device.
Set the P.C.B. under transfer at the correct position.
Check the air pressure.
Others
Refer to “Volume 3 : Troubleshooting” for details.
(2) Check that the maintenance cover, the supply cover, and the safety bar
are closed.
(3) Press the [POWER ON] button to re-supply power to the machine.
Press and hold the [POWER ON] button for a few seconds.
The LED of the [POWER ON] button (-HD50) illuminates in green,
indicating that power to the machine is supplied.
If the green LED does not illuminate (the LED stays in red), re-check
and remove the cause of the emergency stop.
After the [POWER ON] button is pressed, the self-diagnostics func-
tion works on the recognition unit for a few minutes and no operation
becomes available.
Wait until the origin mark “” appears before “RECOGNITION” in
the “ORIGIN MONITOR” field at the “AUTO OPN. MODE <PLACE-
MENT>” display.
(4) After a “” mark has appeared before “RECOGNITION”, perform the
zeroing operation to zero each individual device.
0004-002 2-68 Tg0246-PM-OP
8. Shut-Down Operation (End of Production)
Press the [POWER OFF] button on the operation panel.
Turn off the power breaker ({) located on the front side of the machine to shut
off the power completely.
8. Shut-Down Operation (End of Production)
9910-001 2-69 Tg0246-PM-OP