1OM-1064-002.pdf - 第178页
3. AUTO OPN SUB-MENU Display 9910-001 3-9 Tg0246-PM-OP *4 [TRA Y L [NEUTRAL]/[LOCAL]/[LINE]] and [TRA Y R (NEUTRAL]/ [LOCAL]/[LINE]] Keys (Options) These keys are used to set the multi-layer tray feeder (L) or (R) in the…

3. AUTO OPN SUB-MENU Display
0004-002 3-8 Tg0246-PM-OP
*2 [SIDE A [MOVE]] or [SIDE B [READY]] Key/[SIDE B [MOVE]] or
[SIDE A [READY]] Key
These keys are used to inform the machine that a feeder on the feeder base
is set ready for replacement and component replenishment.
Note: Only the status is displayed on the operation-available side.
Press the [SIDE X [READY] key before performing the compo-
nent replenishment operation. “X” represents either “A” or “B”.
• When one of these keys is pressed with “NOT READY” in *3 and the
[MOVE] button is pressed after the key turns “ON” in blue, the opera-
tion available and opposite sides can be set ready for operation. (The
supply covers and the safety bars are locked and the machine starts run-
ning.)
• When one of these keys is pressed with “READY” in *3 and the [MOVE]
button is pressed after the key turns “ON” in blue, the operation avail-
able and opposite sides can be set ready for component supply opera-
tion. (The X/Y beam moves to its standby position, the supply covers
and the safety bars are unlocked, and the machine is set ready for com-
ponent supply to the tape feeders.)
WARNING
The X/Y beam on the opposite side to the op-
eration available side starts moving.
It is dangerous! Confirm that there is no person
on the opposite side.
When the machine is operated by more than
one person, ensure good communication by giv-
ing loud verbal instructions.
*3 Mode: “READY”, “NOT READY”, or “RUN”
A mode appears, indicating whether or not the machine is set ready for
component supply operation or showing that the machine is in the process
of mode change (“READY” to “NOT READY” or vice versa).
READY : The machine is set ready for component supply opera-
tion. The component supply operation can be performed.
NOT READY : The machine is not set ready for component supply op-
eration.
The supply covers and the safety bars are unlocked, mak-
ing it possible to supply components to the tape feeders.
RUN : The machine is in the progress of mode change
(“READY” to “NOT READY” or vice versa).
The machine is performing a series of operations such
as X/Y movement to the stationary position, X/Y beam
power ON/OFF, and electromagnetic locks ON/OFF.

3. AUTO OPN SUB-MENU Display
9910-001 3-9 Tg0246-PM-OP
*4 [TRAY L [NEUTRAL]/[LOCAL]/[LINE]] and [TRAY R (NEUTRAL]/
[LOCAL]/[LINE]] Keys (Options)
These keys are used to set the multi-layer tray feeder (L) or (R) in the
connection mode (line).
The label in [ ] shows the condition of the multi-layer tray feeder.
[NEUTRAL] : The multi-layer tray feeder is in the same condition as
that set when power is supplied.
[LOCAL] : The multi-layer tray feeder is in the “Local” mode. As
it is separated forcibly from the main machine, the au-
tomatic operation cannot be performed.
Manual operation is possible with the touch panel on
the multi-layer tray feeder side.
[LINE] : The multi-layer tray feeder is connected forcibly to the
main machine.
The multi-layer tray feeder is set ready for automatic
operation.
*5 UPPER MAGAZINE or LOWER MAGAZINE (Options)
These labels indicate whether or not the upper or the lower magazine on
the multi-layer tray feeder is set ready.
ON (Green) : Ready
OFF : Component Supply Possible
Function Keys
*6 [PROGRAM CHANGE] Key
This key is used to change current pattern program.
Refer to “3. Program Change of Section 4” for details.
*7 [SEMI-AUTOMATIC OPERATION] Key
This key is used to call the start-up menu for component placement start-
ing in the middle of pattern program data steps.
The related functions are used to reset the machine to the normal condi-
tion and start up the operation again after power is shut off during opera-
tion or to re-start the operation in the middle of steps after system clear
operation.
*8 [OPERATION MODE] Key
When this key is pressed, the “OPERATION MODE” display opens. Ba-
sically parameters for operation mode are set in the current pattern pro-
gram data. When some of the parameters (feeder alternate cancel, etc.)
must be modified according to situational changes and the required menu
key is pressed at the “OPERATION MODE” display, the corresponding
display opens, enabling the alteration of parameters set in the data boxes
labeled such as “RECOVERY MODE” (reserved function), etc.
*9 [RECOVERY OPN TEACHING OPN] Key
When this key is pressed, the “RECOVERY OPN TEACHING OPN” dis-
play opens, enabling the selection of menu keys to edit or correct pattern
program data, to change the feeding angle of a packaged component, to
edit or correct feeder (B) offset data, etc.
*10 [PRODUCT CHANGE] Key
This key is used to set up the conveyor width, etc.
Refer to “4. Product Change of Section 4” for details.

3. AUTO OPN SUB-MENU Display
*11 [RECALL MESSAGES] Key
When this key is pressed, the “RECALL MESSAGES” display opens,
enabling the selection of menu keys to recall device errors, handling er-
rors, recognition errors, machine information, etc., which occurred in the
past.
Each data is displayed in order of the error occurrence.
Refer to “4. Recall Messages of Section 3 in Volume 4” for details.
*12 [MANAGEMENT DATA] Key
When this key is pressed, the “MANAGEMENT DATA” display opens,
enabling the selection of menu keys to check management data such as
pattern program management data, time management data, component han-
dling error rate data, etc.
It is also possible to check situations such as nozzle bypass rate and nozzles
and feeders whose pick-up rates have deteriorated.
Refer to “3. Management Data of Section 3 in Volume 4” for details.
*13 [TRAY PICK-UP MATRIX] Key (Option)
The matrix data of the multi-layer tray feeder (option) can be referred to
or changed.
*14 [PICK-UP LOCATION] Key
When this key is pressed, the “PICK-UP LOCATION” display appears on
the screen, enabling to teach the component pick-up location through
manual alignment operation.
Refer to “6.9 PICK-UP LOCATION Display of Section 3 in Volume 4”
for details.
9910-001 3-10 Tg0246-PM-OP