1OM-1064-002.pdf - 第123页
3. Confirmation and Procedure of Power Supply Process Messages at Power ON The following messages appear and scroll up in the described order in T able 2.3. T able 2.3 9910-001 2-25 Tg0246-PM-OP No. Messages 1 CPU BOARD …

3. Confirmation and Procedure of Power Supply
Fig. 2.20-4
Fig. 2.20-3
9910-001 2-24 Tg0246-PM-OP
When a “Log In” type is selected and a password is entered, the “MAIN MENU”
display appears on the screen.

3. Confirmation and Procedure of Power Supply
Process Messages at Power ON
The following messages appear and scroll up in the described order in Table
2.3.
Table 2.3
9910-001 2-25 Tg0246-PM-OP
No. Messages
1 CPU BOARD (1) INITIALIZING
2 SERIAL BOARD (1-1) INITIALIZING
3 CPU SYNCHRONOUS PROCESSING (1)
4 SDS BOARD INITIALIZING
5 MOTOR CONTROL BOARD (3-1) INITIALIZING
6 MOTOR CONTROL BOARD (3-2) INITIALIZING
7 MOTOR CONTROL BOARD (3-3) INITIALIZING
8 MEMORY BOARD INITIALIZING
9 TOUCH SCREEN INITIALIZING
10 DATA INITIALIZING
11 CPU SYNCHRONOUS PROCESSING (2)
12 CPU BOARD (2) INITIALIZING
13 I/O BOARD (2-1) INITIALIZING
14 INTERLOCK BOARD INITIALIZING
15 D.D. MOTOR CONTROL BOARD (1) INITIALIZING
16 D.D. MOTOR CONTROL BOARD (2) INITIALIZING
17 D.D. MOTOR CONTROL BOARD (3) INITIALIZING
18 D.D. MOTOR CONTROL BOARD (4) INITIALIZING
19 SYSTEM CLEAR PROCESSING
20 CPU SYNCHRONOUS PROCESSING (3)
21 MOTOR CONTROL BOARD (5) INITIALIZING
22 CPU SYNCHRONOUS PROCESSING (4)
23
RECOGNITION BOARD INITIALIZING
0
%|----+---
20
%---+---
40
%---+---
60
%---+---
80
%---+---|
100
%
********************************
XXXX
KBytes
written
24 CPU SYNCHRONOUS PROCESSING (5)
• When a different memory version is used (when the version is updated to a
new one), the following message appears after No. 8.
Table 2.4
After the memory is converted, processing continues with No. 9.
No. Message
8-1
MEMORY CONVERT PROCESSING
(PLEASE WAIT A MINUTE)

3. Confirmation and Procedure of Power Supply
9910-001 2-26 Tg0246-PM-OP
• When an error is found in the memory or the current version is changed to
an old one, the following messages appear after No. 8.
Table 2.5
No. Messages
8-1
CORRUPT DATA IN MEMORY.
DATA IN MEMORY WILL BE CLEARED.
PLEASE PRESS [SYSTEM CLEAR] BUTTON.
8-2 MEMORY CLEAR PROCESSING
After the memory is cleared, processing continues with No. 9.
Note: When the [SYS CLR] button is pressed, all memory is cleared.
When the above messages are issued, contact our sales personnel.