1OM-1064-002.pdf - 第163页
7. Starting, Emergency Stop, and T emporary Stop (Pause) Operations for Automatic Operation (“P ASS” Mode) (5) Check the surroundings of the machine and confirm safety before start- ing the automatic operation. CAUTION C…

7. Starting, Emergency Stop, and Temporary Stop (Pause) Operations for Automatic Operation (“PASS” Mode)
7. Starting, Emergency Stop, and Temporary Stop
(Pause) Operations for Automatic Operation
(“PASS” Mode)
7.1 Usage
When “PASS” is set in the “PLACEMENT MODE” data box at the “OPERA-
TION DATA” display, the machine does not place any components on a P.C.B.
and passes the P.C.B. over to the output conveyor (Input Conveyor → P.C.B.
Positioning Section → Output Conveyor). (Hierarchical Sequence: “PATTERN
PROGRAM” Display → “PATTERN PROGRAM EDIT” Display → “OP-
ERATION DATA” Display)
7.2 Start Procedure
(1) Perform the following operations.
• Preparation of Pattern Program
(Refer to “5.1 Preparation of Pattern Program of Section 2” for
details)
• Refer to “5.2 Program Change Operation of Section 2” for details
When the production model is selected, the vacuum pump motor stops
automatically.
• Pattern Program Checking for Production Model
(Refer to “5.3 Pattern Program Checking for Production Model of
Section 2” for details.)
“PASS” must be set in the “PLACEMENT MODE” data box at the
“OPERATION DATA” display in the pattern program.
(The highlighted [PASS/PLACE CHANGE] key in the “AUTO OPN.
SUB-MENU” display toggles off.)
• Adjustment of P.C.B. Positioning Section (Ref.: “5.2.2 Adjustment of
P.C.B. Positioning Section of Section 2")
(2) Confirm that the maintenance covers (maintenance covers, supply
covers, safety bars) are closed.
(3) Set the [OPERATION/SET UP] switch to the “OPERATION” side and
remove the selection key from the machine.
(4) Confirm that the LEDs (-HD09) of the [READY] buttons on the front and
rear operation panels are “ON”.
Press the [READY] button to turn it on if necessary.
To set the opposite side ready for operation, select the [SIDE A] or the
[SIDE B] key (Only the opposite side can be selected. Press the [READY]
button in the case of the operation panel.) under the label “(FEEDER
CHANGE-OVER PREPARATION COMPLETE)” at the “AUTO OPN
SUB-MENU” display and press the [MOVE] button. (Hierarchical Se-
quence: “AUTO OPN. MODE (PLACEMENT)” Display → “AUTO
OPN. SUB-MENU” Display)
0004-002 2-64 Tg0246-PM-OP

7. Starting, Emergency Stop, and Temporary Stop (Pause) Operations for Automatic Operation (“PASS” Mode)
(5) Check the surroundings of the machine and confirm safety before start-
ing the automatic operation.
CAUTION
Check carefully that there is no person around
the moving mechanisms of the machine.
(Especially, the other side of machine opera-
tion)
Make sure that no objects remain within the
moving mechanisms of the machine.
(Tools and Parts)
(6) Open the “AUTO OPN. MODE (PLACEMENT)” display and check the
origin marks “”.
Note: When “” marks do not appear beside the devices other than
“INPUT MACHINE”, the automatic operation cannot be started.
• When “” marks appear beside the devices other than “IN-
PUT MACHINE”, proceed to Step (8).
• When “” marks do not appear beside some devices other than
“INPUT MACHINE”, proceed to Step (7).
(7) Press the [ZERO] button.
• The “” marks appear beside all devices except for “INPUT MA-
CHINE”.
(8) Press the [START] button.
• Work requirement and ready signals are sent to the input machine side.
• When the input machine is set ready for operation, it receives the work
requirement signal from the main machine and right after that, P.C.B.’s
start flowing into the input machine and the automatic operation
(“PASS” mode) starts.
When the input machine is not set ready, the machine is set in the
“WAIT” mode.
• When the automatic operation (“PASS” mode) starts, all origin marks
“” disappear and the LED (-HD01) of the [START] button and the
tower light (green) illuminate.
9910-001 2-65 Tg0246-PM-OP

7. Starting, Emergency Stop, and Temporary Stop (Pause) Operations for Automatic Operation (“PASS” Mode)
7.3 Stop Procedure
7.3.1 General Stop Procedure
• Press the [STOP] or the [PAUSE] button.
The operation stops.
7.3.2 Automatic Stop Procedure
• Stop the input machine.
The machine processes all P.C.B.’s on the system line, discharges them, and
stops running automatically.
Notes: (a) When “ENABLE” is set in the “AUTO STOP MODE” at the
“P.C.B. TRANSFER MODE SET-UP” display, the automatic op-
eration stops automatically. (Hierarchical Sequence: “DEVICE
DATA” → “P.C.B. TRANSFER MODE SET-UP” Display)
(b) When a machine of another brand is connected to the system line,
this function may not work.
7.3.3 Emergency Stop Procedure
• To stop the machine immediately in an emergency, press one of the [EMER-
GENCY STOP] buttons.
Power to the loads is shut off and the machine stops running instantaneously.
Refer to “7.5.2 Reset and Start Procedure from Emergency Stop of Section
2” for details on how to reset the machine from emergency stop.
7.4 Possible Operations during Automatic Operation
In the case of the automatic operation (PASS), the possible operations are the
same as the automatic operation (placement).
Refer to “6.5 Operational Displays during Automatic Operation of Section 2”
for details.
9910-001 2-66 Tg0246-PM-OP