1OM-1064-002.pdf - 第155页

6. Starting, Emergency Stop, and T emporary Stop (Pause) Operations for Automatic Operation (“PLACE” Mode) 9910-001 2-57 Tg0246-PM-OP RUN/W AIT PAUSE Possible Operations • Editing and Sav e O pe r ation o f Co mpo nent L…

100%1 / 244
6. Starting, Emergency Stop, and Temporary Stop (Pause) Operations for Automatic Operation (“PLACE” Mode)
6.5 Operational Displays during Automatic Operation
Automatic Operation Sub-Menu
RUN/WAIT PAUSE
Possible
Operations
Editing and Save Operation of Recalled
Data (Recalled Messages)
• RECALL DEVICE ERROR
• RECALL HANDLING ERROR
• RECALL MACHINE INFO
• RECALL COMP. RECOG. ERROR
Editing and Save Operation of Management
Data
Operation Mode
Recovery Operation
Teaching Operation
Change of Carrier Data
Feeder (B) Offset
Editing and Save Operation of Recalled
Data (Recalled Messages)
Editing and Save Operation of Management
Data
Editing and Save Operation of Tray Pick-
Up Matrix Data (Option)
Impossible
Operations
Semi-Automatic Operation (Full Auto Step)
Save Operation of Operation Mode
Save Operation of Recovery/Teaching
Operation Data
Editing and Save Operation of Recalled Data
(Recalled Messages)
Recalled Recognition Error Image
Editing and Save Operation of Tray Pick-Up
Matrix Data (Option)
Shift to the “PRODUCT CHANGE” Display
Shift to the “PROGRAM CHANGE” Display
Shift to the “PICK-UP LOCATION” Display
Semi-Automatic Operation (Full Auto Step)
Save Operation of Recovery/Teaching
Operation Data
Correction of Current Program
Correction of Component Library Data
Shift to the “PRODUCT CHANGE”
Display
Shift to the “PROGRAM CHANGE”
Display
Shift to the “PICK-UP LOCATION
Display
RUN/WAIT PAUSE
Possible
Operations
Zeroing Operation
Manual Subsystem Operation
Manual Axis Operation
Manual Transfer Operation
Impossible
Operations
Shift to the “PROGRAM CHANGE” Display
Shift to the “PRODUCT CHANGE” Display
Shift to the “ZEROING OPERATION” Display
Shift to the “MANUAL SUBSYSTEM
OPERATION” Display
Shift to the “MANUAL AXIS OPERATION”
Display
Shift to the “MANUAL NOZZLE CHANGE
OPERATION” Display
Shift to the “MANUAL TRANSFER
OPERATION” Display
Shift to the “PCB SUPPORT PINS SET-UP
MODE” Display
Shift to the “PROGRAM CHANGE”
Display
Shift to the “PRODUCT CHANGE”
Display
Manual Nozzle Change Operation
Shift to the “PCB SUPPORT PINS SET-
UP MODE” Display
Manual Mode
9910-001 2-56 Tg0246-PM-OP
6. Starting, Emergency Stop, and Temporary Stop (Pause) Operations for Automatic Operation (“PLACE” Mode)
9910-001 2-57 Tg0246-PM-OP
RUN/WAIT PAUSE
Possible
Operations
Editing and Save Operation of Component
Library Data (Not for Current Pattern
Program)
Editing and Save Operation of Component
Library Data (Not for Current Pattern
Program)
Editing and Save Operations of Test Mode
Data other than P.E.C. and Component
Recognition Data
Editing and Save Operation of Offset Data
• Feeder (A) Offset
• Feeder (B) Offset
Impossible Operations
Shift to the "PROGRAM CHANGE" Display
Save Operation of Component Library Data
(Used in Current Pattern Program)
Save Operation of Auto Operation Set-Up Data
Save Operation of Device Data
• P.C.B. Transfer Mode Set-Up
Machine Communication Mode Set-Up
Tray Matrix Mode (Option)
Save Operation of Test Mode
Save Operation of Offset Data
Save Operation of Nozzle Stocker Data
Save Operation of Nozzle Library Information
Shift to the “PROGRAM CHANGE”
Display
Save Operation of Component Library
Data (Used in Current Pattern Program)
Save Operation of Auto Operation Set-Up
Data
Save Operation of Device Data
• P.C.B. Transfer Mode Set-Up
Machine Communication Mode Set-Up
Tray Matrix Mode (Option)
Save Operation of Offset Data
• Offset Data other than Feeder (A) Offset
and Feeder (B) Offset
Save Operation of Nozzle Stocker Data
Save Operation of Nozzle Library
Information
RUN/WAIT PAUSE
Possible
Operations
Editing and Save Operation of Current Pattern
Program Data with Another Name
Editing and Save Operation of Other Data (Not
Current One)
Editing and Save Operation of Current
Pattern Program Data with Another Name
Editing and Save Operation of Other Data
(Not Current One)
Impossible
Operations
Save Operation of Current Pattern Program
Data with Same Name
Save Operation of Current Pattern Program
Data with Same Name
Data Editing
Editing of Pattern Program
Data Editing
Others
6. Starting, Emergency Stop, and Temporary Stop (Pause) Operations for Automatic Operation (“PLACE” Mode)
Special Selection
9910-001 2-58 Tg0246-PM-OP
RUN/WAIT PAUSE
Possible
Operations
Save Operation of Management Data
Save Operation of Recalled Data (Recalled
Messages)
• RECALL DEVICE ERROR
• RECALL HANDLING ERROR
• RECALL MACHINE INFO
• RECALL COMP. RECOG. ERROR
Display of Device Check Data
Machine Program Information
Save Operation of Management Data
Save Operation of Recalled Data (Recalled
Messages)
Display of Device Check Data
Machine Program Information
Zeroing Operation
Manual Subsystem Operation
Manual Axis Operation
Impossible Operations
Save Operation of Recalled Data (Recalled
Messages)
Recalled Recognition Error Image
Editing and Save Operation of Manual Bypass
Data
Display of Device Check Data
• Input Check
• Memory Check
• Output Check
Shift to the “ZEROING OPERATION” Display
Shift to the “MANUAL SUBSYSTEM
OPERATION” Display
Shift to the “MANUAL AXIS OPERATION”
Display
Shift to the “UNIT ADJUSTMENT” Display
Shift to the “OFFSET TEACH” Display
Shift to the “DEVICE TEST” Display
Shift to the “HDD/FDD OPERATION”
Display
Editing and Save Operation of Manual
Bypass Data
Display of Device Check Data
• Input Check
• Memory Check
• Output Check
Shift to the “UNIT ADJUSTMENT”
Display
Shift to the “OFFSET TEACH” Display
Shift to the “DEVICE TEST” Display
Shift to the “HDD/FDD OPERATION”
Display