1OM-1064-002.pdf - 第195页

5. Operation Mode Fig. 3.12 “AL TERNA TE FEEDER MODE” “ENABLE” This appears in the text box when “ON” is set in the “MODE” data field of the label “AL TERNA TE FDR.” at the “COM- PONENT DA T A” display . (Hierarchical Se…

100%1 / 244
5. Operation Mode
9910-001 3-25 Tg0246-PM-OP
5.4 P.E.C. MANUAL ALIGNMENT MODE Display
Described below is how to perform the P.E.C. manual alignment operation
after a P.E.C. recognition error has occurred.
When the [P.E.C. MANUAL ALIGNMENT MODE] key is pressed at the
“OPERATION MODE” display, the following display appears on the screen.
Fig. 3.11
When a P.E.C. recognition error has occurred, the fiducial mark position must
be specified through manual alignment operation. “STANDARD” or
“TRACKBALL” can be selected as a manual alignment mode.
STANDARD : When one of the direction keys is selected on the touch screen
(“MANUAL ALIGNMENT” display) and the [MOVE] but-
ton is pressed, the captured image of the component can be
aligned manually.
TRACKBALL : The mark position (a view on the recognition monitor) can
be specified and aligned manually through track ball opera-
tions.
5. Operation Mode
Fig. 3.12
“ALTERNATE FEEDER MODE”
“ENABLE”
This appears in the text box when “ON” is set in the “MODE”
data field of the label “ALTERNATE FDR.” at the “COM-
PONENT DATA” display. (Hierarchical Sequence: “DATA
EDIT” Display “PATTERN PROGRAM” Display
“PATTERN PROGRAM EDIT” Display “COMPONENT
DATA” Display “COMPONENT DATA EDIT” Display)
“DISABLE”
This appears in the text box when “OFF” is set in the
“MODE” data field of the label “ALTERNATE FDR.” at
the “COMPONENT DATA” display.
[INDV. FDR. ENABLE/DISABLE] Key
When this key is pressed, the “INDIVIDUAL FDR EN-
ABLE/DISABLE” display (Fig. 3.13) appears on the screen.
5.5 ALTERNATE MODE Display
This display allows the operator to determine whether or not the alternate
feeder mode should be used.
Every time a component shortage error occurs at a feeder, the alternate feeder
mode enables the component pick-up position to be shifted automatically to
another alternative one (specified as the substitute), making it possible for
the machine to perform the operation continuously.
When the [ALTERNATE MODE] key is pressed at the “OPERATION MODE”
display, the following display appears on the screen. (Hierarchical Sequence:
“AUTO OPN. MODE <PLACEMENT>” Display “AUTO OPN. SUB-
MENU” Display “OPERATION MODE” Display)
9910-001 3-26 Tg0246-PM-OP
5. Operation Mode
[ENABLE] or [DISABLE] Key
[ENABLE] Key
Select this key to use the alternate feeder mode.
[DISABLE] Key
Select this key not to use the alternate feeder mode.
Note: When “DISABLE” is set, the subsequent alternate
feeder operation is prohibited.
“ALTERNATE OPERATION”
[SUPPLY PRI] Key
Select this key to immediately alternate the feeder to the
one for component replenishment.
[EP DATA]
Select this key to pick up components continuously from
the currently selected feeder.
9910-001 3-27 Tg0246-PM-OP