1OM-1064-002.pdf - 第203页
6. RECOVERY OPN. TEACHING OPN. Display 9910-001 3-34 Tg0246-PM-OP 6.2 COMPONENT LIBRAR Y Display When the [COMPONENT LIBRAR Y EDIT] key is pressed at the “RECOV- ER Y OPN. TEACHING OPN.” display , the following display a…

6. RECOVERY OPN. TEACHING OPN. Display
9910-001 3-33 Tg0246-PM-OP
*5 [CURRENT PROGRAM PL. DATA SORTING] Key
When this key is pressed, the “PLACEMENT DATA SORTING” display
appears on the screen, enabling the sorting of placement order.
Refer to “2.1.4 PLACEMENT DATA SORTING Display and 4.1.3 PLACE-
MENT DATA SORTING Display of Section 2 in Volume 2” for details.
6.1 PATTERN PROGRAM EDIT Display
When the [CURRENT PROGRAM] key is pressed at the “RECOVERY OPN.
TEACHING OPN.” display, the following display appears on the screen.
Notes: (a) When the machine is set in the “RUN”, “WAIT”, or “PAUSE”
mode, the data save operation (saving of changed setting) can-
not be performed. The displayed parameters can only be referred
to.
(b) The -marked functions are optional.
Fig. 3.17
Refer to “4. PATTERN PROGRAM Display of Section 2 in Volume 2” for
details.

6. RECOVERY OPN. TEACHING OPN. Display
9910-001 3-34 Tg0246-PM-OP
6.2 COMPONENT LIBRARY Display
When the [COMPONENT LIBRARY EDIT] key is pressed at the “RECOV-
ERY OPN. TEACHING OPN.” display, the following display appears on the
screen.
Note: When the machine is set in the “RUN”, “WAIT”, or “PAUSE” mode,
the data save operation (saving of changed setting) cannot be performed.
The displayed parameters can only be referred to.
Fig. 3.18
Move the line cursor to the component ID to be corrected and press the [DATA
EDIT] key. The “COMPONENT LIBRARY EDIT” display appears on the
screen.
Refer to “Chapter 3 “Component Library” Displays in COMPONENT LI-
BRARY” for details.

6. RECOVERY OPN. TEACHING OPN. Display
Fig. 3.19
[TAPE A FDR101-139] and [TAPE B FDR201-239] Keys
When either one of these keys is pressed, the corresponding
“COMPONENT CARRIAGE DATA EDIT” display appears
on the screen, enabling you to change the component car-
riage data related to the tape feeders.
[VIB. STICK A FDR141-199] and [VIB. STICK B FDR241-
299] Keys
When either one of these keys is pressed, the corresponding
display appears on the screen, enabling you to change the
component carriage data related to the vibratory stick feeders.
[TRAY L FDR301-599] and [TRAY R FDR601-899] Keys
(Option)
When either one of these keys is pressed, the corresponding
display appears on the screen, enabling you to change the
component carriage data related to the multi-layer tray feeders.
6.3 COMP. CARRIAGE DATA EDIT Display (Simplified
Packaging Direction Change Function)
• When components are supplied after component shortage during automatic
operation and the packaged posture of the supplied components differs from
that of the components being used so far due to unavailability, etc., this
function is used to temporarily change the packaged posture.
Note: Only the limited data for the packaged posture can be changed.
When the [COMP. CARRIAGE DATA EDIT] key is pressed at the “RE-
COVERY OPN. TEACHING OPN.” display, the following display appears
on the screen.
Note: The -marked items are optional.
9910-001 3-35 Tg0246-PM-OP