Programming_mail.pdf - 第112页
III- 38 Programming Manual Part III Inspection Algorithm 1.13 IC_Solder2 1.13.1 Inspection Ov er view IC_Solder2 is the algorithm to inspect lead’s length and shift, solder condition and lifted lead in one inspection win…

III-37
Programming Manual
Part III Inspection Algorithm
1.12.4 LiftedLead Setting Dialog
Press Set in the right side of Algorithm. The dialog shown in Figure 1-40 appears.
The parameter can be set in this dialog. Press Apply to apply the parameter.
After all the settings are completed, press OK.
Figure 1-39 LiftedLead Setting
Figure 1-40 Detail Settings of LiftedLead

III-38
Programming Manual
Part III Inspection Algorithm
1.13 IC_Solder2
1.13.1 Inspection Overview
IC_Solder2 is the algorithm to inspect lead’s length and shift, solder condition and lifted lead in one
inspection window with high accuracy.
It automatically locates “inspection points” (lead end, lead base, pad end) on an IC component.
Inspection fl ow is as following; lead length, lead shift, solder, copper, and lifted lead.
CAUTION
If lead length or lead shift inspection is NG, all the following inspections, solder,
copper and lifted lead inspections are skipped.
CAUTION
IC_Solder2 is not available for two lighting system machine. It is also not valid in
combination with Part III 1.22 AS_Av_LeadLength.
㪈
㪉
㪊
㪋
㪌
㪍
㪈
㪉
㪊
㪋
㪌
㪍
Lead Base Area
Gull Wing Area
Lead End Area
Pad Lead Area
Pad Center Area
Pad End Area
Figure 1-41 Inspection of IC_Solder2
1.13.2 Parameter Setting
Figure 1-42 IC_Solder2

III-39
Programming Manual
Part III Inspection Algorithm
Parameter Description
Lighting
The selected lighting in this fi eld does not infl uence to the inspection result.
Algorithm Select IC_Solder2.
Shift[V1-V8]
Enter the appropriate vector. Any value from V1 to V8 is available.
Select the vector according to the Memorize to fi eld of the Adjust window.
Memorize to -
Table 1-18 Parameter 1 of IC_Solder2
Parameter Description
Lead length judgement
Sets inspection parameters for lead length inspection. For details, refer to Part
III 1.13.3 Setting Procedure Step5.
Lead shift judgement
Sets inspection parameters for lead shift inspection. For details, refer to Part III
1.13.3 Setting Procedure Step6.
Table 1-19 Parameter 2 of IC_Solder2 (Lead Inspection)
Parameter Description
No solder
Sets inspection parameters for solder inspection. For details, refer to Part III
1.13.3 Setting Procedure Step7.
Copper exposure
Sets inspection parameters for copper inspection. For details, refer to Part III
1.13.3 Setting Procedure Step8.
Table 1-20 Parameter 3 of IC_Solder2 (Solder Inspection)
Parameter Description
Pad end brightness
Sets inspection parameters for lifted lead inspection. For details, refer to Part III
1.13.3 Setting Procedure Step9.
Threshold
Sets inspection parameters for lifted lead inspection. For details, refer to Part III
1.13.3 Setting Procedure Step10.
Table 1-21 Parameter 4 of IC_Solder2 (Lifted Lead Inspection)
Parameter Description
Engineer Mode
Engineer Mode enables to set detailed settings for parameters.
To set parameters with bar charts, remove the check mark.
Lead length
Enter measured value in lead length.
Lead width
Enter measured value in lead width.
Range
Search range for an edge between a lead end area and a pad lead area.
This lead Displays measured lead length.
Fat solder OK
Judges heavy solder amount as OK.
Dark solder NG
Judges small solder amount as NG.
Use dryjoint Detects dryjoint.
White body
It is useful to search a component body which is brighter than a lead base.
Table 1-22 Parameter 5 of IC_Solder2 (Detail Setting)
NOTE
Check a radio button. The corresponding histogram appears in the lower right side
of the screen.
.
NOTE
When Inspect is pressed, a colored circle may appear on the left side of the radio
button for some inspecton results. Red refers NG and white refers skip inspection.