11. OPTIONS AND AUXILIARY EQUIPMENT
11.4 Power regeneration converter
POINT
When using the FR-RC-(H) power regenerative converter, refer to "Power
Regeneration Converter FR-RC Instruction Manual (IB(NA)66330)".
When using the power regeneration converter, set "
01" in parameter No.PA02.
(1) Selection
The converters can continuously return 75% of the nominal regenerative power. They are applied to the
servo amplifiers of the 5k to 22kW.
Power regeneration
converter
Nominal
regenerative power
(kW)
Servo amplifier
050
75
100 150
500
300
200
100
50
30
20
Continuous energization time [sec]
Nominal regenerative power (%)
FR-RC-15K 15
MR-J3-500B
MR-J3-700B
FR-RC-30K 30
MR-J3-11KB
MR-J3-15KB
FR-RC-55K 55 MR-J3-22KB
FR-RC-H15K 15
MR-J3-500B4
MR-J3-700B4
FR-RC-H30K 30
MR-J3-11KB4
MR-J3-15KB4
FR-RC-H55K 55 MR-J3-22KB4
11 - 46
11. OPTIONS AND AUXILIARY EQUIPMENT
(2) Connection example
NFB
MC
Servo amplifier
L
11
L21
L1
L
2
L3
SK
ON
MC
BC
NPC
RDY
SE
Alarm
output
RDY
output
A
B
C
5m or less
Operation ready
MC
OFF
EMG
ALM
RA2
FR-RC-(H)
Ready
Power factor improving reactor
(Note 7)
R/L
1
S/L2
T/L
3
B
C
RRX
R
SX
S
TX
T
Phase detection
terminals
(Note 1)
Power regeneration
converter FR-RC-(H)
N/
P/
EM1
RA
DOCOM
DICOM
ALM Trouble
(Note 3)
DOCOM
Forced stop
24VDC
P2P1
(Note 4)
(Note 2)
CN3 CN3
(Note 5)
(Note 6)
Power supply
Note 1. When not using the phase detection terminals, fit the jumpers across RX-R, SX-S and TX-T. If the jumpers remain
removed, the FR-RC-(H) will not operate.
2. When using servo amplifiers of 5kW and 7kW, always remove the lead of built-in regenerative resistor connected
to P terminal and C terminal.
3. When setting not to output Trouble (ALM) with parameter change, configure power supply circuit for turning
magnetic contactor off after detecting an occurrence of alarm on the controller side.
4. Between P
1
and P
2
(P
1
and P for 11kW to 22kW) is connected by default.
5. Stepdown transformer is required for coil voltage of magnetic contactor more than 200V class in 400V class servo
amplifiers.
6. Refer to section 1.3 for the power supply specification.
7. For selection of power factor improving AC reactors, refer to "Power Regeneration Converter FR-RC Instruction Manual
(IB(NA)66330)".
11 - 47
11. OPTIONS AND AUXILIARY EQUIPMENT
(3) Outside dimensions of the power regeneration converters
[Unit : mm]
AA
A
C
F
K
EE
BA
B
E
D
2- D hole
Rating plate
Front cover
Display
panel
window
Mounting foot (removable)
Mounting foot
movable
Cooling fan
Heat generation area outside mounting dimension
Power
regeneration
converter
A AA B BA C D E EE K F
Approx. mass
[kg(Ib)]
FR-RC-15K 270 200 450 432 195 10 10 8 3.2 87
19
(41.888)
FR-RC-H15K
340 270 600 582 195 10 10 8 3.2 90
31
(68.343)
FR-RC-30K
FR-RC-H30K
FR-RC-55K
480 410 700 670 250 12 15 15 3.2 135
55
(121.3)
FR-RC-H55K
(4) Mounting hole machining dimensions
When the power regeneration converter is fitted to a totally enclosed type box, mount the heat generating
area of the converter outside the box to provide heat generation measures. At this time, the mounting hole
having the following dimensions is machined in the box.
[Unit : mm]
(AA)
(BA)
b
a
(2- D hole)
(Mounting hole)
Power
regeneration
converter
a b D AA BA
FR-RC-15K 260 412 10 200 432
FR-RC-H15K
FR-RC-30K 330 562 10 270 582
FR-RC-H30K
FR-RC-55K
470 642 12 410 670
FR-RC-H55K