sh030051g.pdf - 第322页

13 - 21 13. SERVO AMPLIFIERS WI TH A LARGE CAPACITY ( 30k TO 55kW ) 13.2.1 Installation direction and clearan c es CAUTION Install the equipment in the specified di rection. Not doing so can cause a failure. Leave the sp…

100%1 / 424
13 - 20
13. SERVO AMPLIFIERS WITH A LARGE CAPACITY
(
30k TO 55kW
)
13.2 Installation
CAUTION
Stacking in excess of the limited number of products is not allowed.
Install the equipment to incombustibles. Installing them directly or close to
combustibles will led to a fire.
Install the equipment in a load-bearing place in accordance with this Instruction
Manual.
Do not get on or put heavy load on the equipment to prevent injury.
Use the equipment within the specified environmental condition range. (For the
environmental conditions, refer to section 13.1.3.)
Provide an adequate protection to prevent screws, metallic detritus and other
conductive matter or oil and other combustible matter from entering the converter
unit
drive unit.
Do not block the intake/exhaust ports of the converter unit drive unit. Otherwise,
a fault may occur.
Do not subject the converter unit drive unit to drop impact or shock loads as they
are precision equipment.
Do not install or operate a faulty converter unit drive unit.
When the product has been stored for an extended period of time, consult
Mitsubishi.
When treating the converter unit drive unit, be careful about the edged parts
such as the corners of the converter unit
drive unit.
POINT
Explanations on the following item are the same as those for servo amplifiers
with 22kW or less. Refer to the section below for details.
Keep out foreign materials Refer to section 2.2.
Cable stress Refer to section 2.3.
SSCNET cable laying Refer to section 2.4.
Parts Having Service Lives Refer to section 2.6.
13 - 21
13. SERVO AMPLIFIERS WITH A LARGE CAPACITY
(
30k TO 55kW
)
13.2.1 Installation direction and clearances
CAUTION
Install the equipment in the specified direction. Not doing so can cause a failure.
Leave the specified clearances between the converter unit/drive unit and the
control box inside walls or other equipment. Not doing so can cause a failure.
(1) Installation
POINT
Make sure to connect a drive unit to the right side of a converter unit as
shown in the diagram.
80mm or
more
Side view
Drive unitConverter unit
Front view
100mm or
more
120mm or more
30mm or
more
30mm or
more
Cooling fan
wind direction
Air
intake
(2) Mounting dimensional diagram
9.5
Converter unit
punched hole
Drive unit
punched hole
4-M6 screw
300
20
260
281
Approx. 9.5
Approx. 20
4-M6 screw
W1
W3
W2
W4
Approx. W5
Approx. W3
W5
[Unit: mm]
Drive unit model
Dimensions
W1 W2 W3 W4 W5 A
MR-J3-DU30KB, 37KB,
45KB4, 55KB4
300 260 20 281 9.5 M6
MR-J3-DU30KB4,
37KB4
240 120 60 222 9 M5
(3) Others
When using heat generating equipment such as the regenerative option, install them with full consideration
of heat generation so that the converter unit and drive unit is not affected.
Install the converter unit and drive unit on a perpendicular wall in the correct vertical direction.
13 - 22
13. SERVO AMPLIFIERS WITH A LARGE CAPACITY
(
30k TO 55kW
)
13.2.2 Inspection
WARNING
Before starting maintenance and/or inspection, turn off the power and wait for 20
minutes or more until the charge lamp turns off. Then, confirm that the voltage
between L
and L is safe with a voltage tester and others. Otherwise, an
electric shock may occur. In addition, always confirm from the front of the converter
unit whether the charge lamp is off or not.
CAUTION
Any person who is involved in inspection should be fully competent to do the work.
Otherwise, you may get an electric shock. For repair and parts replacement,
contact your safes representative.
POINT
Do not test the converter unit drive unit with a megger (measure insulation
resistance), or it may become faulty.
It is recommended to make the following checks periodically.
1) Check for loose terminal block screws. Retighten any loose screws.
2) Check the servo motor bearings, brake section, etc. for unusual noise.
3) Check the cables and the like for scratches and cracks. Perform periodic inspection according to operating
conditions.
4) Check the servo motor shaft and coupling for misalignment.