13. SERVO AMPLIFIERS WITH A LARGE CAPACITY
(
30k TO 55kW
)
(2) Brake unit parameter setting
Normally, changing parameters of the FR-BU2-(H) is not necessary. Whether a parameter can be changed
or not is listed below.
Parameter
Change
possible/
impossible
Remarks
No. Name
0 Brake mode switchover Impossible Do not change the parameter.
1 Monitor display data selection Possible Refer to FR-BU2-(H) Brake Unit
Instruction Manual.
2 Input terminal function selection 1 Impossible Do not change the parameter
3 Input terminal function selection 2
77 Parameter write selection
78 Cumulative energization time
carrying-over times
CLr Parameter clear
ECL Alarm history clear
C1 For manufacturer setting
(3) Connection example
POINT
Connecting PR terminal of the brake unit to L terminal of the converter unit
results in a brake unit malfunction. Always connect the PR terminal of the
brake unit to the PR terminal of the resistor unit.
(a) Combination with FR-BR-(H) resistor unit
POINT
To use brake units with a parallel connection, use two sets of FR-BU2-(H)
brake unit. Combination with other brake unit results in alarm occurrence or
malfunction.
Always connect the master and slave terminals (MSG and SD) of the two
brake units.
Do not connect as shown below.
N/
P/
Brake unit
Brake unit
Converter unit
L
L
N/
P/
Connecting two cables to
P and N terminals
N/
P/
Brake unit
Brake unit
Converter unit
L
L
N/
P/
Passing wiring

13 - 92
13. SERVO AMPLIFIERS WITH A LARGE CAPACITY
(
30k TO 55kW
)
NFB
Drive unitConverter unit
L1
L
2
L3
L
11
L21
(Note 1)
Power supply
L
L
L
L
1MC1
2MC2
CNP1
EM1
3
20
SDPlate
DICOM
10
DOCOM
5
DICOM
ALM15
CN3
RA1
Forced stop
(Note 2)
MC
CN1
1
DICOM
5
DOCOM
6
DICOM
2ALM
7EM1
9
DOCOM
(Note 2)
RA2
N/
P/
BUE
SD
PR
B
C
A
SD
MSG
(Note 4)
(Note 7)
FR-BU2-(H)
FR-BR-(H)
P
PR
TH2
TH1
(Note 6)
Terminal
block
(Note 12)
(Note 11)
(Note 10)
N/
P/
BUE
SD
PR
B
C
A
SD
MSG
FR-BU2-(H)
(Note 6)
FR-BR-(H)
P
PR
L11
L
21
(Note 5)
P
1
P
2
(Note 3)
L
L
(Note 9)
RA1
RA2 RA3
Drive
unit
Converter
unit
Controller
forced stop
RA4
Servo motor
thermal relay
(Note 8)
MC
SK
(Note 2)
Forced stop
EM1
Operation
ready
OFF/ON
24VDC
24VDC
(Note 4)
(Note 7)
(Note 11)
(Note 10)
TH2
TH1

13 - 93
13. SERVO AMPLIFIERS WITH A LARGE CAPACITY
(
30k TO 55kW
)
Note 1. For power supply specifications, refer to section 13.1.3.
2. Configure the circuit to turn OFF the forced stop (EM1) of the drive unit and the converter unit at the same time.
3. Always connect P
1 and P2 terminals (Factory-wired). When using the power factor improving DC reactor, refer to section 13.9.6.
4. Connect P/
and N/ terminals of the brake unit to a correct destination. Wrong connection results in the converter unit and
brake unit malfunction.
5. For the converter unit and the drive unit of 400V class, a stepdown transformer is required.
6. Contact rating: 1b contact, 110VAC_5A/220VAC_3A
Normal condition: TH1-TH2 is conducting. Abnormal condition: TH1-TH2 is not conducting.
7. Contact rating: 230VAC_0.3A/30VDC_0.3A
Normal condition: B-C is conducting/A-C is not conducting. Abnormal condition: B-C is not conducting/A-C is conducting.
8. Connect the thermal relay censor of the servo motor.
9. Do not connect more than one cable to each L
and L terminals of TE2-1 of the converter unit.
10. Always connect BUE and SD terminals (Factory-wired).
11. Connect MSG and SD terminals of the brake unit to a correct destination. Wrong connection results in the converter unit and
brake unit malfunction.
12. For connecting L
and L - terminals of TE2-1 of the converter unit to the terminal block, use the cable indicated in (3) (d) of
this section.