sh030051g.pdf - 第73页
3 - 18 3. SIGNALS AND WI RING (a) When using the supplied cable connec tion lever 1) The servo amplifier is packed with the cable connection lever. a) 54932-0000 (Molex) [Unit: mm] MXJ 54932 7.7 4.7 Approx. 3 4.9 10 20.6…

3 - 17
3. SIGNALS AND WIRING
2) CNP2
CNP2 is the same as MR-J3-100B or smaller capacities. Refer to (1) (b) of this section.
(4) Insertion of cable into Molex and WAGO connectors
Insertion of cable into 54928-0610, 54928-0520, 54928 (Molex) connectors and 721-207/026-000, 721-205/
026-000 and 721-203/026-000 (WAGO) connectors are as follows.
The following explains for Molex, however use the same procedures for inserting WAGO connectors as
well.
POINT
It may be difficult for a cable to be inserted to the connector depending on
wire size or bar terminal configuration. In this case, change the wire type or
correct it in order to prevent the end of bar terminal from widening, and then
insert it.
How to connect a cable to the servo amplifier power supply connector is shown below.

3 - 18
3. SIGNALS AND WIRING
(a) When using the supplied cable connection lever
1) The servo amplifier is packed with the cable connection lever.
a) 54932-0000 (Molex)
[Unit: mm]
MXJ
54932
7.7
4.7
Approx. 3 4.9
10
20.6
3.46.5
Approx. 4.9
Approx. 7.7
Approx.3.4
b) 231-131 (WAGO)
[Unit: mm]
20.3
10
16
7.6
3
6.5
3.4
4.9
17.5
1.5
1.3

3 - 19
3. SIGNALS AND WIRING
2) Cable connection procedure
1) Attach the cable connection lever to the housing.
(Detachable)
2) Push the cable connection lever in the direction
of arrow.
3) Hold down the cable connection lever and insert
the cable in the direction of arrow.
4) Release the cable connection lever.
Cable connection lever