11 - 52 11. OPTIONS AND AUXILI ARY EQUIPMENT (4) Selection example of wires used for wiring POINT Selection condition of wi re size is as follows. Wire type: 600V Polyvinyl chloride insulated wire (IV wire) Construction …

11 - 51
11. OPTIONS AND AUXILIARY EQUIPMENT
(b) 400V class
P
1
(Note 8)
Stepdown
transformer
DOCOM
RA1
EM1
C
B
R/L11
3-phase
380 to
480VAC
S/L
21
T/L
31
R2/L1
S2/L
22
R2/L12
T2/L
32
S2/L2
(Note 3)
P24
SD
RDYB
RDYA
RSO
SE
A
T2/L
3
R/L
11
S/L
21
T/MC1
RES
SD
(Note 1)
L
11
L
21
P( )
N( )
U
V
W
(Note 1)
EM1
(Note 2)
RA1
RA2
24VDC
power
supply
Thermal
relay
OHS2
OHS1
CN2
MC
NF
FR-CVL FR-CV-H
MC
RA1 RA2
EM1
OFF
ON
RESET
SK
MC
(Note 1)
Servo motorServo amplifier
(Note 4)
Servo system
controller
(Note 5)
(Note 1)
(Note 7)
DICOM
N/L
P/L
U
V
W
(Note 6)
Note 1. Configure a sequence that will shut off main circuit power at an emergency stop or at FR-CV-H or servo amplifier alarm
occurrence.
2. For the servo motor with thermal relay, configure a sequence that will shut off main circuit power when the thermal relay
operates.
3. For the servo amplifier, configure a sequence that will switch the servo on after the FR-CV-H is ready.
4. For the FR-CV-H, the RSO signal turns off when it is put in a ready-to-operate status where the reset signal is input.
Configure a sequence that will make the servo inoperative when the RSO signal is on.
5. Configure a sequence that will make a stop with the emergency stop input of the servo system controller if an alarm occurs
in the FR-CV-H. When the servo system controller does not have an emergency stop input, use the forced stop input of the
servo amplifier to make a stop as shown in the diagram.
6. When using the servo amplifier of 7kW or less, make sure to disconnect the wiring of built-in regenerative resistor (2kW or
less: P
and D, 3.5k to 7kW: P and C).
7. When using the servo amplifier of 11k to 22kW, make sure to connect P
1
and P( ). (Factory-wired.)
8. Stepdown transformer is required for coil voltage of magnetic contactor more than 200V class servo amplifiers.

11 - 52
11. OPTIONS AND AUXILIARY EQUIPMENT
(4) Selection example of wires used for wiring
POINT
Selection condition of wire size is as follows.
Wire type: 600V Polyvinyl chloride insulated wire (IV wire)
Construction condition: One wire is constructed in the air
(a) Wire sizes
1) Across P-P(
), N-N( )
The following table indicates the connection wire sizes of the DC power supply (P, N terminals)
between the FR-CV and servo amplifier.
Total of servo amplifier capacities [kW] Wires[mm
2
]
1 or less 2
2 3.5
5 5.5
7 8
11 14
15 22
22 50
The following table indicates the connection wire sizes of the DC power supply (P(
), N( )
terminals) between the FR-CV-H and servo amplifier.
Total of servo amplifier capacities [kW] Wires[mm
2
]
1 or less 2
2 3.5
5 5.5
7 8
11 8
15 22
22 22
2) Grounding
For grounding, use the wire of the size equal to or greater than that indicated in the following
table, and make it as short as possible.
Power regeneration common converter Grounding wire size [mm
2
]
FR-CV-7.5K to FR-CV-15K 14
FR-CV-22K FR-CV-30K 22
FR-CV-37K FR-CV-55K 38
FR-CV-H22K FR-CV-H30K 8
FR-CV-H37K FR-CV-H55K 22

11 - 53
11. OPTIONS AND AUXILIARY EQUIPMENT
(b) Example of selecting the wire sizes
When connecting multiple servo amplifiers, always use junction terminals for wiring the servo amplifier
terminals P, N. Also, connect the servo amplifiers in the order of larger to smaller capacities.
1) 200V class
R2/L
1
S2/L
2
T2/L3
R/L
11
S/L21
T/MC1
P/L
N/L
P
N
50mm
2
Overall wiring length 5m or less
First unit:
50mm
2
assuming that the total of servo amplifier
capacities is 27.5kW since 15kW + 7kW + 3.5kW
+ 2.0kW = 27.5kW.
P
N
P
N
P
N
22mm
2
8mm
2
2mm
2
22mm
2
8mm
2
3.5mm
2
2mm
2
Junction terminals
Wire as short as possible.
Second unit:
22mm
2
assuming that the total of servo amplifier
capacities is 15kW since 7kW + 3.5kW + 2.0kW =
12.5kW.
Third unit:
8mm
2
assuming that the total of servo amplifier
capacities is 7kW since 3.5kW + 2.0kW = 5.5kW.
Fourth unit:
2mm
2
assuming that the total of servo amplifier
capacities is 2kW since 2.0kW = 2.0kW.
FR-CV-55K Servo amplifier (15kW)
Servo amplifier (7kW)
Servo amplifier (3.5kW)
Servo amplifier (2kW)
(Note)
(Note)
(Note)
(Note)
Note. When using the servo amplifier of 7kW or less, make sure to disconnect the wiring of built-in regenerative resistor (3.5kW or
less: P-D, 5k/7kW: P-C).
2) 400V class
R2/L
1
S2/L2
T2/L
3
R/L
11
S/L
21
T/MC1
P/L+
N/L-
P
N
22mm
2
P
N
P
N
P
N
14mm
2
5.5mm
2
2mm
2
14mm
2
5.5mm
2
2mm
2
2mm
2
FR-CV-55K
Servo amplifier (7kW)
Servo amplifier (3.5kW)
Servo amplifier (2kW)
(Note)
Overall wiring length 5m or less
First unit:
22mm
2
assuming that the total of servo amplifier
capacities is 27.5kW since 15kW + 7kW + 3.5kW
+ 2.0kW = 27.5kW.
Junction terminals
Wire as short as possible.
Second unit:
14mm
2
assuming that the total of servo amplifier
capacities is 15kW since 7kW + 3.5kW + 2.0kW =
12.5kW.
Third unit:
5.5mm
2
assuming that the total of servo amplifier
capacities is 7kW since 3.5kW + 2.0kW = 5.5kW.
Fourth unit:
2mm
2
assuming that the total of servo amplifier
capacities is 2kW since 2.0kW = 2.0kW.
Servo amplifier (15kW)
(Note)
(Note)
Note. These servo amplifiers are development forecasted.