sh030051g.pdf - 第48页
1 - 27 1. FUNCTIONS AND CONFIGURATIO N (6) MR-J3-700B(4) R S T L 21 L 11 UV W C P L 1 L 2 L 3 CN5 CN3 CN2 CN1A CN1B CN4 P 2 P 1 Line noise filter (FR-BLF) (Note 3) Power supply Magne tic contac tor (MC) No-f use b reaker…

1 - 26
1. FUNCTIONS AND CONFIGURATION
(5) MR-J3-350B4
MR-J3-500B(4)
R S T
L21
P1
P
2
CN3
CN2
CN1A
CN1B
CN4
CN5
(Note 2)
L11
UVW
CP
L1
L
2
L
3
Regenerative option
Line noise filter
(FR-BLF)
(Note 3)
Power supply
Magnetic
contactor
(MC)
No-fuse breaker
(NFB) or fuse
MR Configurator
Personal
computer
Servo amplifier
(Note 2)
Power factor
improving DC
reactor
(FR-BEL-(H))
Servo system
controller or Front axis
servo amplifier CN1B
Rear servo amplifier
CN1A or Cap
(Note 1)
Battery
MR-J3BAT
Servo motor
Junction
terminal
block
Note 1. The battery (option) is used for the absolute position detection system in the position control mode.
2. The AC reactor can also be used. In this case, the DC reactor cannot be used. When not using DC reactor, short P
1 and P2.
3. Refer to section 1.3 for the power supply specification.

1 - 27
1. FUNCTIONS AND CONFIGURATION
(6) MR-J3-700B(4)
R S T
L
21
L
11
UVW
CP
L
1
L
2
L
3
CN5
CN3
CN2
CN1A
CN1B
CN4
P2
P1
Line noise filter
(FR-BLF)
(Note 3)
Power supply
Magnetic
contactor
(MC)
No-fuse breaker
(NFB) or fuse
(Note 2)
(Note 2)
Power factor
improving DC
reactor
(FR-BEL-(H))
Servo amplifier
Regenerative option
Servo motor
Junction
terminal
block
MR Configurator
Personal
computer
Servo system
controller or Front axis
servo amplifier CN1B
Rear servo amplifier
CN1A or Cap
(Note 1)
Battery
MR-J3BAT
Note 1. The battery (option) is used for the absolute position detection system in the position control mode.
2. The AC reactor can also be used. In this case, the DC reactor cannot be used. When not using DC reactor, short P
1 and P2.
3. Refer to section 1.3 for the power supply specification.

1 - 28
1. FUNCTIONS AND CONFIGURATION
(7) MR-J3-11KB(4) to MR-J3-22KB(4)
Line noise filter
(FR-BLF)
(Note 3)
Power supply
R S T
Magnetic
contactor
(MC)
No-fuse
breaker (NFB)
or fuse
Regenerative option
L
21
Servo amplifier
Servo motor
(Note 2)
L11
UVW
CP
L1
L
2
L3
CN4
MR Configurator
Personal
computer
CN5
CN3
CN2
Junction
terminal
block
Servo system
controller or Front axis
servo amplifier CN1B
Rear servo amplifier
CN1A or Cap
CN1A
CN1B
P1
P
(Note 2)
Power factor improving
DC reactor (FR-BEL-(H))
(Note 1)
Battery
MR-J3BAT
Note 1. The battery (option) is used for the absolute position detection system in the position control mode.
2. The AC reactor can also be used. In this case, the DC reactor cannot be used. When not using DC reactor, short P
1 and P.
3. Refer to section 1.3 for the power supply specification.