SM482PLUS_Admin(Eng_Ver2.8).pdf - 第168页
6-50 Multi-Functional Placer SM482( L) PLUS Administrator’s Guide 6.7. PCB Block Block Refers to a unit in the separate form which comp oses one comple te PCB. It is composed in the form of One Board or array PCB. It is …

6-49
Board Definition
<Confirm> Button
You can manually enter the 2D barcode ID by entering the 2D barcode
information in the edit box above and clicking this button.
Warning You must enter the accurate 2D barcode information since
the equipment will freeze and stop production once it
receives the ‘Cannot Proceed’ command from the MES
server due to incorrect input.
If the 2D barcode recognition fails after manual processing, remove the corresponding
PCB manually.
Warning If you remove the board manually or take measures against
the error while the machine is in ready state, you may get
injured. Release the ready state and manually remove the
board or take measures against the error while the machine
is in idle state.

6-50
Multi-Functional Placer SM482(L) PLUS Administrator’s Guide
6.7. PCB Block
Block
Refers to a unit in the separate form which composes one complete PCB. It is composed in
the form of One Board or array PCB. It is in the same form physically as the existing PCB.
Block Fiducial
Refers to the fiducial representing one block defined to compensate the coordinates for
placement points, etc., in the block.
The concept is the same as that of the existing panel fiducial. However, if only one panel
fiducial exists in the block, the number of block fiducial is equal to the number of blocks.
Block PCB
Refers to the one complete PCB. It is composed in the form of One Board or array PCB.
PCB
One PCB may be composed of one or several blocks.

6-51
Board Definition
Clicking the <Block> button will display the following dialog box with which the PCB
model type is set.
Figure6.12 “Block PCB” dialog box
<1.Use> check box
Selected when performing configuration of the model type and block.
<2. Block Setting> group
<3. Block Type> combo box
Select the type of model configuration. Three types can be selected as follows;