SM482PLUS_Admin(Eng_Ver2.8).pdf - 第266页

8-14 Multi-Functional Placer SM482( L) PLUS Administrator’s Guide  <Enable Home Offs et> chec k box When this check box is se lected, the MMI r eads the Y of fset value from the IT Feeder System and corrects the Y…

100%1 / 604
8-13
Feeder Setup
<Part Outline> check box
If this check box is selected, when the fiducial camera is moved to the position of the
corresponding feeder to check the pickup position, the outline image that considers the
angle at which the corresponding part is picked up is displayed on the SMVision
window.
<Part Offset> button
Clicking this Button will automatically reflect the pickup offset of the corresponding
part on the pickup coordinate when there are parts with pickup offset among the parts
supplied by the currently installed tape feeders.
<Offset Part> button
Selected when applying the pickup offset to the same tape feeder collectively after
changing the pickup coordinate of the installed tape feeder.
8-14
Multi-Functional Placer SM482(L) PLUS Administrator’s Guide
<Enable Home Offset> check box
When this check box is selected, the MMI reads the Y offset value from the IT Feeder
System and corrects the Y coordination of the pickup point. Therefore, this function
can be used only when the IT Feeder System and Device Net board are installed in the
machine.
<Display> button
Displays the shape of the feeder that is installed on the feeder base graphically.
8-15
Feeder Setup
<Panorama View> button
In the case of a large part for which pocket teaching is impossible, its entire shape is
not displayed in the vision window. In this case, it is possible to display the part shape
in on one vision window by performing split recognition of the part shape and
composing the split images into one using this function.
<Cancel> button
Close the dialog box.
Panorama General