14-26 Multi-Functional Placer SM482( L) PLUS Administrator’s Guide H1F-R3: Theta axis (H3, H4) of the front gantry H1F-R5: Theta axis (H5, H6) of the front gantry ST1F-W : W idth control motor of the front work station(F…

14-25
Machine Calibration
14.3.1. Axis Home Calibration
Sets the limit position of each axis to move. When this button is clicked on, the following
dialog box is displayed.
Memo In order to access this menu, the user must execute login with
authorization from the ‘Service Engineer’.
Figure14.8 “System Axis Limit Info.” dialog box
<Motor Select> list box
Select the motor axis for which to set the limit. Available axes are as follows.
G1F-X: X axis of the front gantry
G1F-Y: Y axis of the front gantry
H1F-Z1: Z axis of head 1 of the front gantry
H1F-Z2: Z axis of head 2 of the front gantry
H1F-Z3: Z axis of head 3 of the front gantry
H1F-Z4: Z axis of head 4 of the front gantry
H1F-Z5: Z axis of head 5 of the front gantry
H1F-Z6: Z axis of head 6 of the front gantry
H1F-M1: Mirror axis of the front gantry
H1F-R1: Theta axis (H1, H2) of the front gantry

14-26
Multi-Functional Placer SM482(L) PLUS Administrator’s Guide
H1F-R3: Theta axis (H3, H4) of the front gantry
H1F-R5: Theta axis (H5, H6) of the front gantry
ST1F-W: Width control motor of the front work station(F2)
<Software Limit> group
<X-Y Axis Limit Automatic Searching…> button
Finds the limit of the X and Y axes automatically and checks whether to apply the
changed value.
<Skew Compensation> button
Activated when selecting the Y axis. It is used to perform the skew compensation. For
further details, refer to “12.3.2 Skew compensation”.
<Calibrate Home> button
Automatically finds and reflects the home position of the motor selected from the
<Motor Select> list box.
<CALIBRATE HOME ALL AXIS> button
Automatically finds and reflects the home positions of all axes.

14-27
Machine Calibration
<FIND LIMIT ALL AXIS> button
Automatically finds and reflects the home positions of all axes.
<Home Info.> group
If the mirror axis is selected, the <Home Offset> edit box will be enabled. It is used to
perform calibration for the mirror axis.
<Head Z HomeSensor> Group
Sets whether there is a Z-axis home sensor for the head or not.
<Update> button
Transmits the set data to the machine and closes the dialog box.
<Close> button
Ignores the set data and closes the dialog box.
Caution If calibration is done again, the machine might not operate
properly unless the items related to the equipment position,
such as pick up position, ANC, placement origin are taught
again as the home position is changed.
After calibration, be sure to teach the items related to
position again.
14.3.1.1. Procedure
Axis Home Calibration method is as follows.
1. Click the <CALIBRATE HOME ALL AXIS> button.
(Proceed in the following order: Head Homing → Gantry Homing → Conveyor)
2. After confirming that there is no object inside the machine or on the conveyor, click
the <OK> button.