Multi-Functional Placer SM482(L)P PLUS Administrator’s Guide
<Valve Check> button
Check the solenoid valve to find that the ‘Vacuum On’ and ‘Blow Off’ are executed
properly. Insert the CN40 nozzle in the head spindle’s nozzle holder manually and
check the valve.
The following dialog box shows the results of the solenoid valve checks using the
CN040 nozzle.
<Try> combo box
Select the number of times to execute ‘Vacuum On’ and ‘Blow Off’. It is
recommended to execute ‘Vacuum On’ and ‘Blow Off’ at least 100 times in order
to obtain effective results.
<Head> combo box
Selects the gantry to check the solenoid valve.
<Spindle> combo box
Selects the head to check the solenoid valve. Selecting ‘All’ will check all heads
of the gantry selected from the <Head> combo box.
<Test> button
Selecting this button will check ‘Vacuum On’ and ‘Blow Off’ for heads selected
from the <Head> combo box and <Spindle> combo box as many times as selected
from the <Try> combo box and will display the results in a graph.
16-11
Diagnosis
<Detail> button
Clicking this button will display the dialog box indicating the result of the check
for the selected head as a statistical numerical value.
<Vacuum Check> group
Vac_sat [mmHg]
Indicates the average vacuum level of the corresponding heads after
performing the ‘Vacuum On’ operation. (Average: -580 mmHg)
Build Time [ms]
Indicates the time taken to reach 90% of the vacuum level.
Standard Dev [3σ]
Indicates the dispersion (3σ) of “Build Time’.
Min Build Time [ms]
Indicates the minimum value of the ‘Build Time’.
Max Build Time [ms]
Indicates the maximum value of the ‘Build Time’.
<Blow Check> group
Build Time [ms]
Indicates the time taken to reach 90% blow creation.
Standard Dev [3σ]
Indicates the dispersion (3σ) of “Build Time’.
16-12
Multi-Functional Placer SM482(L)P PLUS Administrator’s Guide
Min Build Time [ms]
Indicates the minimum value of the ‘Build Time’.
Max Build Time [ms]
Indicates the maximum value of the ‘Build Time’.
<Save As> button
Clicking this button will execute the dialog box used to select the path to save the
result data as a text file.
<Vacuum Pressure>
Indicates the vacuum level in graphic form when the vacuum level of the
corresponding head reached 90% after performing the ‘Vacuum On’ operation
X-axis
Indicates the average vacuum level of the heads after performing the ‘Vacuum
On’ operation. (Average: -580 mmHg)
Y- ax is
Refers to the count corresponding to the vacuum level which is the index of
the X-axis. The sum of the counts indicated by bar graphs is the same as the
count selected from the <Try> combo box.
Check whether the vacuum is created up to the required level while watching the
graph. If the result value exists within the blue area, it is normal. However, if it is
indicated in the white area, there is a problem. In this case, it is necessary to
observe the vacuum level continuously. If the result value is indicated in the grey
area, it is abnormal. In this case, contact our STS or local agent for a precise
check.
For the CN040 nozzle, if the vacuum level is higher than 400 mmHg, it is possible
to operate normally.